Use and Care Manual

User Manual Page 27
Installation
Instructions
NOTE
Check that air conditioner is tilted back about
1-1/4” to 1-5/8” (tilted about 3° to 4° downward
to the outside). After proper installation,
condensate should not drain from the
over ow drain hole during normal use, correct
the slope otherwise (Fig.15).
Window Sash
About 1
1/4”
to 1
5/8”
Measure from
the cabinet
edge
Side
Louvers
Window Sill
Sill Angle
Bracket
Fig. 15
Fig. 14B
Right
Left
Locknut
Sill Angle
Bracket
Flat Head Bolt
2 Each Required For
Each Support Bracket
1/2” Long Screws
and Locknuts
2. Assemble sill angle bracket to support brackets
at the marked position (Fig. 15B). Hand tighten,
but allow for any changes later.
3. Install support brackets (with sill angle brackets
attached) to correct hole in bottom of cabinet
as shown in Fig. 16.
4. Tighten all 6 bolts securely.
6 Extend Window Filler Panels
1. Carefully raise window to expose  ller panel
locking screws. Loosen screws so  ller panels
slide easily.
2. Extend panels to fill window opening
completely. Tighten locking screws on top
(Fig. 17).
3. Close window behind top angle.
Fig. 16
1/2” Long
Screws and
Locknuts
Fig. 17
7/16"
Locking
Screw and
Washer
Locking Screw