Datasheet

N 3 KV2
HI - WALL
INDOOR UNIT
Indoor unit RAS- M07N3KV2-E B10N3KV2-E B13N3KV2-E B16N3KV2-E B22N3KV2-E M24N3KV2-E
Air Flow m
3
/h - l/s C 516 - 143 516 - 143 563 - 156 684 - 190 1080 - 300 1134 - 315
Sound pressure level (h/l) dB(A) C 38/25 38/25 39/26 45/30 47/35 49/37
Sound power level (h/l) dB(A) C 51/38 51/38 52/39 58/43 60/48 62/50
Air Flow m
3
/h - l/s H 570 - 158 570 - 158 630 - 175 743 - 206 1098 - 305 1152 - 320
Sound pressure level (h/l) dB(A) H 38/27 39/27 40/28 45/31 47/35 49/37
Sound power level (h/l) dB(A) H 51/40 52/40 53/41 58/44 60/48 62/50
Dimensions (HxWxD) mm 275x790x205 275x790x205 275x790x205 275x790x205 320x1050x228 320x1050x228
Weight kg 9 9 9 9 13 13
Flare connections (gas - liquid) 3/8” - 1/4” 3/8” - 1/4” 3/8" - 1/4" 1/2" - 1/4" 1/2" - 1/4" 1/2" - 1/4"
N3KV2
Physical data Indoor unit
IAQ Filter
Toshiba IAQ
filtration system.
Modern stylish and compact design.
Memorization of the desired operation parameters with one touch of
'' my comfort'' button.
Self cleaning function to remove moist from the internal
components of the unit.
Toshiba DC hybrid inverter technology controls and adjust the
capacity supplied by the air conditioner.
TOSHIBA | 35
C = cooling mode H = heating mode h/l= high / low speed