Datasheet

TOSHIBA | 49
Outdoor unit HWS- 804H-E
Single Phase Units
1104H-E 1404H-E 1104H8-E
Three Phase Units
1404H8-E 1604H8-E
Hydro unit combination HWS- 804XWH**E 1404XWH**E 1404XWH**E 1404XWH**E 1404XWH**E 1404XWH**E
Heating Power * - (Nominal / Maximum) 8,00 / 8,52 11,20 / 14,63 14,00 / 16,74 11,20 / 14,73 14,00 / 15,77 16,00 / 16,76
Power input - (Nominal / Maximum) 1,79 / 2,01 2,30 / 3,24 3,11 / 3,95 2,34 / 3,14 3,16 / 3,55 3,72 / 3,89
COP 4,46 / 4,24 4,88 / 4,52 4,50 / 4,24 4,80 / 4,69 4,44 / 4,44 4,30 / 4,30
Cooling Power * - (Maximum) 9,19 13,82 15,00 13,15 15,44 16,39
Power input - (Maximum) 2,59 3,49 4,07 3,34 4,39 4,98
EER 3,55 3,96 3,69 3,94 3,52 3,29
Heating Power **- (Maximum) kW 8,13 13,62 14,26 13,93 15,07 15,77
Power input - (Maximum) kW 2,42 3,76 4,00 3,76 4,24 4,58
COP W/W 3,36 3,62 3,56 3,70 3,56 3,44
Cooling Power **- (Nominal / Maximum) kW 6,00/7,00 10,00/10,24 11,00/11,78 10,00/10,16 11,00/12,02 13,00/12,84
Power input - (Nominal / Maximum) kW 1,94/2,42 3,26/3,29 3,81/4,07 3,26/3,17 3,81/4,13 4,80/4,63
EER W/W 3,10/2,89 3,07/3,11 2,89/2,89 3,07/3,21 2,89/2,91 2,71/2,78
HWS_XWH / HWS_H
System capacities
Domestic hot water tank HWS- 804XWHM3-E 804XWHT6-E 804XWHT9-E 1404XWHM3-E 1404XWHT6-E 1404XWHT9-E
To be used with size 80 80 80 110-140-160 110-140-160 110-140-160
Leaving water temperature °C H 20 ~ 55°C 20 ~ 55°C 20 ~ 55°C 20 ~ 55°C 20 ~ 55°C 20 ~ 55°C
°C C 7 ~ 25°C 7 ~ 25°C 7 ~ 25°C 7 ~ 25°C 7 ~ 25°C 7 ~ 25°C
Dimensions (HxWxD) mm 925x525x355 925x525x355 925x525x355 925x525x355 925x525x355 925x525x355
Weight Kg 50 50 50 54 54 54
Sound pressure level dB(A) 27 27 27 29 29 29
Electric back up heater capacity kW 3 6 9 3 6 9
Electric back up heater supply V-ph-Hz 220/230-1-50 380/400-3N-50 380/400-3N-50 220~230-1-50 380/400-3N-50 380/400-3N-50
Maximum current A 13 13 x 2 13 x 3 13 13 x 2 13 x 3
HWS_XWH
Hydro units data
HWS- 1501CSHM3-E 2101CSHM3-E 3001CSHM3-E
Water volume litres 150 210 300
Max water temperature °C 75 75 75
Electric heater kW 2,75 2,75 2,75
Power supply V-ph-Hz 220/230-1-50 220/230-1-50 220/230-1-50
Height mm 1090 1474 2040
Diameter mm 550 550 550
Weight Kg 31 41 60
Material Stainless steel Stainless steel Stainless steel
HWS_CSHM
Domestic hot water tanks data
Model Name Description Functions
TCB-PCIN3E Output signal PCB Boiler operation output signal, Alarm output signal, Defrost output signal, Compressor operation output signal
TCB-PCMO3E Input signal PCB Room thermostat input, Emergency stop input
HWS-AMS11E Wired RC Wired Remote controller for Room air temperature control
Accessories
The capacities in this catalogue are calculated based on following conditions:
*Heating: Leaving hot water temperature: 35°C (ΔT 5°C). Outdoor air temperature: 7 °C DB / 6 °C WB.
**Heating: Leaving hot water temperature: 45°C (ΔT 5°C). Outdoor air temperature: 7 °C DB / 6 °C WB.
*Cooling: Leaving cold water temperature: 18°C (ΔT 5°C). Outdoor air temperature: 35°C DB.
**Cooling: Leaving cold water temperature: 7°C (ΔT 5°C). Outdoor air temperature: 35°C DB.
The sound pressure level is given at 1 m distance from outdoor units, and 1.5 m distance from hydro units.
C = Cooling mode H = Heating mode
Outdoor unit
HWS-
804H-E
Single Phase Units
1104H-E 1404H-E 1104H8-E
Three Phase Units
1404H8-E 1604H8-E
Dimensions (HxWxD) mm 890x900x320 1340x900x320 1340x900x320 1340x900x320 1340x900x320 1340x900x320
Weight Kg 63 92 92 93 93 93
Sound pressure Level dB(A) 49 49 51 50 51 52
Power supply V-ph-Hz 220/230-1-50 380/400-3N-50
Operating range °C -20 ÷ 43
Minimum pipe length m 5
Maximum pipe length m 30
Maximum height difference m ± 30
Chargeless pipe length m 30
Compressor type DC Twin rotary
Refrigerant R410A
Flare connections (gas-liquid) 5/8" - 3/8"
HWS_H
Outdoor units data