Stage 1: From 1 January 2013
Air conditioners, shall correspond to minimum energy efficiency requirements.
Requirements for minimum energy efficiency
SEER SCOP (Aver. heating saeson)
If GWP of refrigerant > 150 3,6 3,24
If GWP of refrigerant ≤ 150 3,4 3,06
The requirements on sound power shall relate to the standard rating conditions are listed below:
REQUIREMENTS FOR MAXIMUM SOUND POWER LEVEL
Rated capacity ≤ 6kW 6 < Rated capacity ≤ 12kW
Indoor sound
power
level in db (A)
Outdoor sound
power level in
db (A)
Indoor sound
power
level in db (A)
Outdoor sound power
level in db (A)
30 65 65 70
Stage 2: From 1 January 2014
Air conditioners, shall correspond to minimum energy efficiency requirements.
REQUIREMENTS FOR MINIMUM ENERGY EFFICIENCY
Air conditioners, except double and
single duct air conditioners
Double duct air conditioners Single duct air conditioners
SEER
SCOP
(Aver.
heating saeson)
EER rated COP rated EER rated COP rated
If GWP of refrigerant > 150 for 6kW 4,6 3,8 2,6 2,6 2,6 2,04
If GWP of refrigerant ≤ 150 for 6kW 4,14 3,42 2,34 2,34 2,34 1,84
If GWP of refrigerant > 150 for 6-12kW 4,3 3,8 2,6 2,6 2,6 2,04
If GWP of refrigerant ≤ 150 for 6-12kW 3,87 3,42 2,34 2,34 2,34 1,84
New European Eco Design Directive
The objective of the new European Eco Design Directive is the integration of environmental
aspects into product design with the aim of improving the environmental performance of the product throughout its
whole life cycle. Energy efficiency values, together with the sound levels of the units, will be reflected in the new Energy
label to allow end-customers to do better and environmentally sensible choice.
Apart from the user's behavior, there are two complementary ways of reducing the energy
consumed by products: the labeling to raise the awareness of consumers and the energy efficiency requirements
imposed to products on the design phase.