Datasheet

Outdoor unit: RAS-M14GAV-E
Performances in Cooling mode
Operating status
Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)
EER label
Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.
2 unit operation
10 10 1,95 1,95 1,4 3,9 4,4 230 1070 1290 1,43 4,9 5,84 3,64 A
13 10 2,33 1,67 1,4 4 4,5 230 1080 1300 1,43 4,94 5,89 3,70 A
Performances in Heating mode
Operating status
Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)
EER label
Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.
2 unit operation
10 10 2,15 2,15 0,9 4,3 5,1 170 980 1230 1,06 4,39 5,51 4,39 A
13 10 2,5 1,9 0,9 4,4 5,2 170 1010 1250 1,06 4,53 5,6 4,36 A
Combination ratings (size 14) heat pump
Performances in Cooling mode
Operating status
Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)
EER label
Unit A Unit B Unit A Unit B 1,4 4,0 4,8 260 960 2150 1,61 4,50 9,54
2 unit operation
07 07 2,00 2,00 1,4 4,0 4,8 260 960 2150 1,61 4,50 9,54 4,17 A
10 07 2,65 1,95 1,4 4,6 6,0 260 1200 2150 1,61 5,61 9,54 3,83 A
10 10 2,55 2,55 1,4 5,1 6,1 260 1410 2150 1,61 6,45 9,54 3,62 A
13 07 3,38 1,82 1,4 5,2 6,1 260 1440 2170 1,61 6,45 9,63 3,61 A
13 10 3,00 2,20 1,4 5,2 6,2 260 1440 2170 1,61 6,45 9,63 3,61 A
16 07 3,60 1,60 1,4 5,2 6,2 260 1440 2170 1,61 6,45 9,63 3,61 A
16 10 3,25 1,95 1,4 5,2 6,2 260 1440 2170 1,61 6,45 9,63 3,61 A
13 13 2,60 2,60 1,4 5,2 6,2 260 1440 2170 1,61 6,45 9,63 3,61 A
16 16 2,85 2,35 1,4 5,2 6,2 260 1440 2170 1,61 6,45 9,63 3,61 A
Performances in Heating mode
Operating status
Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)
EER label
Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.
2 unit operation
07 07 2,70 2,70 0,9 5,4 8,0 200 1190 2480 1,24 5,35 11,12 4,54 A
10 07 3,79 1,61 0,9 5,4 8,2 200 1190 2530 1,24 5,35 11,22 4,54 A
10 10 2,70 2,70 0,9 5,4 8,2 200 1190 2530 1,24 5,35 11,22 4,54 A
13 07 3,64 1,96 0,9 5,6 8,2 200 1190 2530 1,24 5,35 11,22 4,71 A
13 10 3,11 2,49 0,9 5,6 8,3 200 1190 2530 1,24 5,35 11,22 4,71 A
16 07 3,76 1,84 0,9 5,6 8,3 200 1190 2530 1,24 5,35 11,22 4,71 A
16 10 3,24 2,36 0,9 5,6 8,3 200 1190 2530 1,24 5,35 11,22 4,71 A
13 13 2,80 2,80 0,9 5,6 8,3 200 1190 2530 1,24 5,35 11,22 4,71 A
16 16 2,93 2,67 0,9 5,6 8,3 200 1190 2530 1,24 5,35 11,22 4,71 A
Outdoor unit: RAS-M18UAV-E
Combination ratings (size 18) heat pump
Performances in Cooling mode
Operating status
Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)
EER label
Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max.
3 unit operation
10 10 10 1,7 1,7 1,7 2,2 5,1 6,3 420 1340 1970 2,4 6,07 8,74 3,81 A
13 10 10 2,14 1,53 1,53 2,2 5,2 6,5 420 1340 2100 2,4 6,07 9,32 3,88 A
16 10 10 2,46 1,37 1,37 2,2 5,2 6,5 420 1340 2100 2,4 6,07 9,32 3,88 A
13 13 10 1,92 1,92 1,37 2,2 5,2 6,5 420 1340 2100 2,4 6,07 9,32 3,88 A
Performances in Heating mode
Operating status
Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)
EER label
Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max.
3 unit operation
10 10 10 2,23 2,23 2,23 2,2 6,7 7,5 420 1580 1950 2,4 7,16 8,74 4,24 A
13 10 10 2,63 2,08 2,08 2,2 6,8 7,7 420 1600 2030 2,4 7,25 9,01 4,25 A
16 10 10 2,95 1,93 1,93 2,2 6,8 7,7 420 1600 2030 2,4 7,25 9,01 4,25 A
13 13 10 2,44 2,44 1,93 2,2 6,8 7,7 420 1600 2030 2,4 7,25 9,01 4,25 A
Outdoor unit: RAS-3M18SAV-E
Combination ratings (size 18) heat pump
Performances in Cooling mode
Operating status
Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)
EER label
Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D Min. Rated Max. Min. Rated Max. Min. Rated Max.
4 unit operation
10 10 10 10 1,7 1,7 1,7 1,7 3 6,8 7,5 500 1950 2300 2,9 8,74 10,2 3,49 A
13 10 10 10 2,16 1,55 1,55 1,55 3 6,8 7,5 500 1950 2300 2,9 8,74 10,2 3,49 A
16 10 10 10 2,55 1,42 1,42 1,42 3 6,8 7,5 500 1950 2300 2,9 8,74 10,2 3,49 A
13 13 10 10 1,98 1,98 1,42 1,42 3 6,8 7,5 500 1950 2300 2,9 8,74 10,2 3,49 A
Performances in Heating mode
Operating status
Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)
EER label
Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D Min. Rated Max. Min. Rated Max. Min. Rated Max.
4 unit operation
10 10 10 10 1,8 1,8 1,8 1,8 2 7,2 8,4 500 1630 2110 2,90 7,31 9,36 4,42 A
13 10 10 10 2,23 1,66 1,66 1,66 2 7,2 8,4 500 1630 2110 2,90 7,31 9,36 4,42 A
16 10 10 10 2,53 1,56 1,56 1,56 2 7,2 8,4 500 1630 2110 2,90 7,31 9,36 4,42 A
13 13 10 10 2,06 2,06 1,54 1,54 2 7,2 8,4 500 1630 2110 2,90 7,31 9,36 4,42 A
Outdoor unit: RAS-4M23SAV-E
Combination ratings (size 23) heat pump
42