E6581277c Remote Keypad Instruction Manual RKP002Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of Remote Keypad. 2. Read this manual before installing or operating the Remote Keypad. Keep it in a safe place for reference. 3. All information contained in this manual are subject to change without notice. Please confirm the latest information on our web site “www.inverter.co.jp”.
E6581277c Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users, damages to assets, and for proper use of the device. Read the instruction manual attached to the inverter along with this instruction manual to completely understand the safety precautions, the symbols and indications shown below. Please adhere to the contents of these manuals at all times.
E6581277c Limitation of use Safety precaution Never use this unit with any device other than TOSVERT series inverters. Doing so may cause an accident. Handling in general Danger Never Disassemble Prohibited Mandatory Never disassemble, modify or repair the product. Disassembling the product may cause electric shocks, fire or injuries. For repairs, call your sales/repair agency. Do not put or insert foreign objects such as waste cable, bars, or wires into the product.
E6581277c Operations Danger Prohibited Mandatory Do not apply a dropping shock or other physical shocks. Otherwise, damage or malfunction will result. Do not pull on the cable and connector It may cause damage or error. Even if this product is deactivated by an unusual event such as tripping, an operating error, power outage, etc. do not bring any regions of your body into contact with the inverter terminals when power is supplied to the inverter.
E6581277c Preface Thank you for purchasing Remote Keypad (RKP002Z ) for TOSVERT series inverters. Using this product, panel operation, display and adjustment of the inverter can be remotely controlled from up to 5 meters away. You can copy data from one place to another and then execute data comparison between the inverter and the memory of Remote Keypad or between the memories of Remote Keypad itself.
E6581277c Table of contents 1. Overview・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 2. Names and functions of main parts ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 7 3. Connection and start-up・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 8 4. Functions in detail ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 9 4.1. Procedure to switch the operation mode ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 9 4.2.
E6581277c 1. Overview The following seven functions are available with Remote Keypad. 1. Function to serve as remote operation panel. Remote Keypad can be used as a remote operation panel for the inverter. 2. Copying function Data can be copied from one memory to another memory among the four memories, three (memories A, B, C) on Remote Keypad and one on the inverter.
E6581277c 2. Names and functions of main parts The drawings below show names and functions of main parts. Front view RUN lamp PRG lamp MON lamp EASY lamp *2 Display Lights when an ON command is issued but no frequency signal is sent out. It blinks when operation is started. Lights when the inverter is in parameter setting mode. Lights when the inverter is in monitor mode. Lights when the inverter is in EASY mode. Displays setting, device status, trip information, etc.
E6581277c Operation keys and their functions in “COPY MODE” The operation key’s functions in “COPY MODE” are explained in the following table. Operation key Function RUN Memory A key (Exclusive key for simple copying) In the simple copying function, this key is used to specify memory A of Remote Keypad as the origin of transmission data.
E6581277c 4. Functions in detail Remote Keypad can be used as remote operation panel (“REMOTE KEYPAD MODE”) or parameter back-up device (“COPY MODE”). When the “COPY MODE” lamp is lit when turning power on, Remote Keypad operates in “COPY MODE”, otherwise in “REMOTE KEYPAD MODE”. 4.1. Procedure to switch the operation mode According to the procedure described in “3. Connection and start-up”, turn on the power of Remote Keypad while holding down the [ENT] key of Remote Keypad. Operation mode changes. 4.2.
E6581277c 4.3.1. Copying function “copy” The data stored in a memory can be copied to another memory selected from among four memories (the inverter's memory and Remote Keypad memories A, B, and C). Remote Keypad can not be used to copy parameters from one inverter to another inverter of a different series. N.B.: To copy the data to the inverter’s memory, do it when the inverter has stopped. If you copy the data to the inverter while the inverter is running, some of the parameters fail to be copied.
E6581277c 4.3.2. Simple copying function The data stored in the memory A, B or C of Remote Keypad can be copied to the inverter's memory with simple operation of two keys to select one of the memories A, B and C. Use this function to set the same parameters to more than two inverters. Remote Keypad can not copy parameters to from one inverter to another inverter of a different series. What differs from the “Copying function” in Section 4.3.
E6581277c 4.3.3. Comparing function “comp” This function enables the operator to compare data stored in two memories selected from among four memories (the inverter’s memory and Remote Keypad memories A, B, and C) as well as to search for parameters that differ from each other. The comparing function cannot be used for editing parameters because it is provided only for searching parameters that differ from each other. Use the “REMOTE KEYPAD MODE” function described in section 4.2 to edit parameters.
E6581277c 4.3.4. Memory protection function “prot” The memory protection function protects the selected memory from being overwritten. When this function is initiated copying data to the memory is prohibited. Reading the memory data is permitted. When all the memories are initialized by memory initialization function (clr), the LED indications are as follows: “in”, “a”, “b”, “c” = “off”, “sup” = “on” This is also the default setting at the time of shipment.
E6581277c 4.3.5. Memory initializing function clr A selected one of the memories either memory A, B, C of Remote Keypad is enable to be initialized with this function. In addition, all memories including system memory of Remote Keypad is also enable to be initialized.
E6581277c 4.3.6. Remote Keypad parameter editing function This function allows the user to edit the parameters of Remote Keypad. Remote Keypad parameter list Title Function Description f-01 Software version displaying Display shows the software version of Remote Keypad. f-02 Automatic comparing function Automatic comparing function can be turned on or off.
E6581277c 5. Before making a service call If a problem arises, please see the following trouble-shooting tables. If the problem can not be solved, please contact a Toshiba distributor. 5.1. Error message Malfunction indications: Indicated by flashing LED display Error Code Problem and Solutions raMe RAM built in Remote Keypad is abnormal. If the same indication appears after resetting Remote Keypad, it needs to be repaired. roMe ROM built in Remote Keypad is abnormal.
E6581277c 5.3. Warning indications Warning indications: Indicated by flashing LED display. Warning Code Problem and Solutions prot The target memory to copy data or to initialize is write protected. Copying any data to the memory or initializing the memory cannot be executed. Press the [ESC] key to cancel. deVe The type of device is different (different in series or voltage class or capacity of inverter). Press the [ENT] key to copy between two inverters of different capacity or voltage class.
E6581277c 6.
E6581277c Mounting Mount Remote Keypad on the front of the panel board as illustrated below. On the front of the panel board, cut the area shown below for mounting Remote Keypad. Then, fix Remote Keypad on the panel board with the mounting screws (M3 x 12) supplied as accessories. (M3 screw tightening torque: 0.6 Nּm) 10.4 98.0 Upper side 35.9 4.6 16.4 4–φ4.0 hole 63.
E6581277c 7. Specifications Item Part number Applicable model Communication Specifications RKP002Z Model with either an RS485 (2-wire type) connector or a common serial connector (optional) with a baud rate of 9600, 19200 or 38400bps.