No.
No. MIIXR0002EAC IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without written permission. (2) The contents of this manual are subject to change without prior notice and without our legal obligation.
No. MIIXR0002EAC Table of Contents Page 1 INTRODUCTION................................................................................................................ 1 1.1 1.2 1.3 2 REFERENCES ..................................................................................................... 1 DEFINITIONS ....................................................................................................... 1 ACRONYMS, ABBREVIATIONS AND SYMBOLS .......................................
No. MIIXR0002EAC 8.1.1 Media Storage Directory IOD Modules................................................................ 9 8.1.2 Media Storage XA IOD Modules.......................................................................... 9 8.1.3 XA IOD Modules ................................................................................................ 10 8.2 DICOM FILE META INFORMATION ................................................................................ 11 8.2.
No. MIIXR0002EAC 1 Introduction This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography Systems. It is intended to provide the reader with the knowledge of how to integrate this product within DICOM compliant equipments. It details the DICOM Service Classes, Information Objects, and Application Profiles which are supported by this product.
No. MIIXR0002EAC 1.
No. MIIXR0002EAC 2 Implementation Model 2.1 Application Data Flow Diagram Transfer of X-ray Examination DICOM Recording CD-R Medium Review of X-ray Examination DICOM Reader Legend Application Entity Local Real-World Activity File-set Creator (FSC) File-set Reader (FSR) Local Relationship Figure 1 2.2 Functional Definitions of AE's 2.2.1 DICOM Recording The DICOM Recording supports the following tasks: • Builds DICOM XA Information Objects.
No. MIIXR0002EAC 2.2.2 DICOM Reader The DICOM Reader supports the following tasks: 2.3 • Reads the DICOMDIR file that represents the contents of the data as recorded. • Displays the ordered list of patient and image identifying information or icon images. • Reads the selected image SOP instance from the CD-R media and displays it on the monitor of the DICOM Reader. • Reads the File-set of the CD-R media and writes it onto the local storage of DICOM Reader.
No. MIIXR0002EAC 2.3.2 Operation 2.3.2.1 Transfer of X-ray Examination The operation for manual transfer of X-ray examination is described below: STEP-1: Select the images or the patient to be transferred. STEP-2: Request transfer. STEP-3: Insert the blank CD-R media. STEP-4: Request recording the transferred images onto the CD-R media. 2.3.2.2 Review of X-ray Examination The operation for manual review of X-ray examination is described below: STEP-1: Insert the CD-R media to be review.
No. MIIXR0002EAC 3 AE Specifications 3.1 DICOM Recording Specification The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage Service, File Format Class and the Media Storage Application Profile.
No. MIIXR0002EAC 3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relevant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator. This AE reads the DICOMDIR from the CD-R media and reads the SOP instances from the CD-R media. 3.2.
No. MIIXR0002EAC 5 Extensions, Specializations, and Privatizations of SOP Classes and Transfer Syntaxes Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set. Note: Settings and changes are performed by Toshiba Service Personnel at the time of installation of the Digital Fluorography System.
No. MIIXR0002EAC 8 X-Ray Angiographic Information Object Definition 8.1 Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Table 5 Object Module / key DICOM File Meta Information Reference Usage1 8.2.1 M Basic Directory Information Object Definition File-set Identification Module 8.3.1 M Directory Information Module 8.3.2 U Definition of Specific Directory Records PATIENT keys 8.4.
No. MIIXR0002EAC 8.1.3 XA IOD Modules Table 7 Information Entity Module Reference Usage1 Patient Patient Module 8.5.1 M Study General Study Module 8.5.2 M Study Patient Study Module 8.5.3 U Series General Series Module 8.5.4 M Equipment General Equipment Module 8.5.5 M Image General Image Module 8.5.6 M Image Image Pixel Module 8.5.7 M Image Contrast/bolus Module 8.5.8 C Image Cine Module 8.5.9 C Image Multi-frame Module 8.5.
No. MIIXR0002EAC 8.2 DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Table 8 Attribute Name Tag Type File Preamble No Tag 1 Always set DICOM Prefix No Tag 1 Always set ("DICM") Group Length (0002, 0000) 1 Always set File Meta Information Version (0002, 0001) 1 Always set (0x0001) Media Storage SOP Class UID (0002, 0002) 1 Always set ("1.2.840.10008.1.3.
No. MIIXR0002EAC 8.3.
No. MIIXR0002EAC 8.4.2 STUDY keys Table 13 Attribute Name Tag Type Study Date (0008, 0020) 1 Always set Study Time (0008, 0030) 1 Always set Study Description (0008, 1030) 2 Length=0 when no entry is made Study Instance UID (0020, 000D) 1C Always set Study ID (0020, 0010) 1 Always set Accession Number (0008, 0050) 2 Length=0 when no entry is made 8.4.
No. MIIXR0002EAC 8.4.
No. MIIXR0002EAC 8.5 XA Information Object Definisions 8.5.1 Patient Module Table 16 Attribute Name Tag Type Patient's Name (0010, 0010) 2 Always set except for urgent patient Patient ID (0010, 0020) 2 Always set Patient's Birth Date (0010, 0030) 2 Length=0 when no entry is made Patient's Sex (0010, 0040) 2 Always set Patient Comments (0010, 4000) 3 Length=0 when no entry is made 8.5.
No. MIIXR0002EAC 8.5.4 General Series Module Table 19 Attribute Name Tag Type Modality (0008, 0060) 1 Always set ("XA") Series Instance UID (0020, 000E) 1 Always set Series Number (0020, 0011) 2 Always set Series Date (0008, 0021) 3 Always set Series Time (0008, 0031) 3 Always set Performing Physician's Name (0008, 1050) 3 Length=0 when no entry is made Series Description (0008, 103E) 3 Always set 8.5.
No. MIIXR0002EAC 8.5.
No. MIIXR0002EAC 8.5.
No. MIIXR0002EAC 8.5.13 XA Positioner Module Table 28 Attribute Name Tag Type Attribute Description Distance Source to Detector (0018, 1110) 3 Always set [mm] Estimated Radiographic Magnification (0018,1114) 3 Always set Positioner Motion (0018, 1500) 2C Positioner Primary Angle (0018, 1510) 2 Always set [degree] Positioner Secondary Angle (0018, 1511) 2 Always set [degree] Factor 8.5.