ASME B 16.5 class 150 dimensions:
Meter size
(inch)
L1
(inch)
L2
(inch)
L3
(inch)
No. of
bolts
Weight
(lbs)
1/2
7.87
6.77
8.54
4
approx. 9.0
1
7.87
7.01
9.13
4
approx. 14.0
1-1/4
7.87
7.32
9.65
4
approx. 18.0
1-1/2
7.87
7.36
9.88
4
approx. 18.0
2
7.87
7.80
10.79
4
approx. 27.0
2-1/2
7.87
7.99
11.50
4
approx. 36.0
3
7.87
8.39
12.13
4
approx. 42.0
4
9.84
8.98
13.50
8
approx. 62.0
5
9.84
9.41
14.41
8
approx. 71.0
6
11.81
10.04
15.55
8
approx. 91.0
8
13.78
10.94
17.72
8
approx. 137.0
10
17.72
11.85
19.84
12
approx. 205.0
12
19.69
13.35
22.83
12
approx. 313.0
14
21.65
13.58
24.09
12
approx. 401.0
16
23.62
14.49
25.91
16
approx. 507.0
18
23.62
15.39
27.91
16
approx. 614.0
EN1092-1 PN 16 dimensions:
Meter size
(mm)
L1
(mm)
(L2)
(mm)
L3
(mm)
No. of
bolts
Weight
(kg)
15
200
170
218
4
approx. 4.0
25
200
176
239
4
approx. 5.5
32
200
184
252
4
approx. 8.0
40
200
185
255
4
approx. 8.5
50
200
199
277
4
approx. 13.0
65
200
204
292
4
approx. 15.0
80
200
222
314
8
approx. 19.5
100
250
229
334
8
approx. 24.5
125
250
240
366
8
approx. 29.0
150
300
252
392
8
approx. 36.0
200
350
277
442
12
approx. 53.5
250
450
302
502
12
approx. 81.5
300
500
332
555
12
approx. 123.5
350
550
341
586
16
approx. 164.0
400
600
364
644
16
approx. 213.0
450
600
387
697
20
approx. 247.5
Note1: Eye bolts are provided at the top for flowmeters sized 8" (200mm) or above, and further, a roll-prevention base is
provided for flowmeters sized 10" (250mm) or larger.
Note2: Cable glands are not provided for LF654 of cFMus approved type.
Note3: 1 inch = 25.4mm
Figure 6. Separate type detectors LF654
Meter sizes 1/2" (15) to 18" (450mm) for ISO lay length
Unit: inch (mm)