1.
Braking setting functions
f342
: Braking mode selection
f343
: Release frequency
f344
: Release time
f345
: Creeping frequency
f346
: Creeping time
-Function
Setting functions to control braking timing.
- Parameter setting for braking setting function
Title Function Setting range Default setting
f342
Braking mode selection
0: Disabled
1: Enabled (forward run)
2: Enabled (reverse run)
3: Enabled (operating direction)
0
f343
Release frequency f240 ~ 20.0 [Hz] 3.0
f344
Release time 0.00 ~ 2.50 [s] 0.05
f345
Creeping frequency f240 ~ 20.0 [Hz] 3.0
f346
Creeping time 0.00 ~ 2.50 [s] 0.10
- Parameter setting of contact output signal for braking (ex. To use RY-RC output)
Title Function Setting range Setting value
f130
Output terminal
selection 1A
(RY-RC)
0 ~ 255
46: BR (Braking sequence output)
or
47: BRN (Inversion of braking sequence output)
Note) In case of others output terminal, it is deferent from parameter title.
RY-RC: f131
FLA-FLB-FLC: F132