User Manual Portable Air Conditioner Before using your TOSOT Portable Air Conditioner please read this user manual in its entirety.
Welcome to the TOSOT Direct Family! We’re extremely happy to welcome you as a new member of our family! Please read the tips below before using your product for the first time. Tips for First-Time Use 1. The portable air conditioner is a heavy object, which needs two or more people to lift and install. Failure to do so could result in injury or other accidents. 2. Allow the unit to sit upright for at least 3-4 hours before powering on.
Table of Contents Safety and Instructions ------------------------------------------- 01 Installation and Setup ------------------------------------------- 01 Electrical Safety Warning --------------------------------------- 02 Parts Description --------------------------------------------------- 05 Operation -----------------------------------------------------------Control Panel ----------------------------------------------------Remote Control -------------------------------------------------Combination
Safety and Instructions Please read all instructions before use and save this user manual for future reference. A digital version can be obtained from Customer Support. Your safety and the safety of others are very important to us. We have provided many important safety messages throughout this manual and on the appliance itself. Always read and follow all posted safety messages.
● Only use the appliance in an upright position. Make sure the angle of inclination <10°. Always place the appliance on a stable, flat, level surface to prevent the air conditioner from overturning. Electrical Safety Warning ● If the power cable is damaged, it must be replaced by the manufacturer or an authorized technical service center in order to avoid all risk. ● Do not damage, alter, excessively bend, twist, pull or heat the power cord. ● Do not cover the power cord with a rug or carpeting.
LCDI Power Plug (Leakage Current Detection and Interruption) The power cord used with this air conditioner contains a current detection device designed to reduce the risk of fire. In the event that the power supply cord is damaged, it cannot be repaired. The power supply cord must be replaced with a replacement cord received from the manufacturer by a trained service technician.
● Open space around the air conditioner should be at least 12 inches (30cm) to ensure airflow. ● Please keep the air inlet and air outlet clean and free from obstacles. ● During operation, close doors and windows to improve the cooling effect in the room. ● Please put the air conditioner on smooth and flat ground to avoid noise and vibration. ● Avoid direct sunlight exposure.
Parts Description 1 2 3 1 Control Panel 2 Airflow Louver 3 Handles 4 Filter 5 Air Inlet 6 Continuous Drainage Port 7 Power Cord 8 Power Cord Hooks 9 Manual Drainage Port 10 Wheels 5 T-ON AUTO COOL DRY FAN 6 HEAT 7 T-OFF OPER H AUTO SWING SLEEP LOCK SPEED ON/OFF MODE FAN SWING SLEEP TIMER 8 9 10 05 Remote Control
Operation Control Panel 3 1 2 4 5 1 Fan Button 4 Timer Button 2 Swing Button 5 Mode Button 3 +/- Button 6 On/Off Button 06 6
1 Fan Button Pressing this button will cycle the fan speed through one of 4 fan modes, as shown below: auto fan high speed medium speed low speed 2 Swing Button Press this button and the airflow louver will swing up & down automatically. Press it again to turn off the swing function. 3 ON/OFF Button Press to power the air conditioner ON or OFF.
Remote Control The max range of the remote control is 25 feet with no obstacles or interference from other devices, such as wireless phones or fluorescent lamps. The air conditioner will emit a beep sound if the signal from the remote has been received successfully.
3 +/- Button ● Pressing the “+” or “-” button will increase/decrease the set temperature by 1°F. Holding the button for 2 seconds will cause the temperature to change rapidly. Release the button once your desired temperature is reached. ● After pressing the Timer button, each press of the +/- button will increase/ decrease the time by 0.5 hours. Holding the button for 2 seconds will cause the timer to change rapidly. Release the button once your desired time setting has been reached.
Combination Buttons Light Function Press and hold the “+” and “FAN” buttons simultaneously for 3 seconds to turn the lights on the air conditioner on or off. The default setting after being powered on is for the lights to be on. Child Lock Function Press the “+” and “-” buttons simultaneously to enter the child lock function. While in this mode, the remote control will display a LOCK symbol and will not send any signal to the air conditioner.
Installation Tools Required Saw Phillips head screwdriver Tape measure Scissors Pencil Parts List Accessory kit for window installation Window panel Adjustment panel Joint Insect Guard Fixed Clip x 2pcs Exhaust Hose Screw x 4pcs Bracket Rear Clip Mounting Plate x 2pcs Foam Seal A (non adhesive) 11 Exhaust cover Foam Seal B (adhesive type) Extension panel Rain Guard x 2pcs
Accessory kit for installing the drain hose Drain connector Drain Hose Others T-ON COOL DRY FAN ON/OFF T-OFF OPER H AUTO X-FAN SLEEP LOCK SPEED MODE FAN X-FAN SLEEP TIMER Remote Control Power Cord Hook x2pcs Installing Your AC Here are the detailed instructions for installing the window panel into sliding sash or hung windows. For certain windows, such as a casement window, you will need to improvise several steps of the installation as each specific window will be different. 1.
2. Attach the insect guard to the back side of the window panel. Push in to ensure that it fits securely. If you do not want to install the rain guard, skip to Step 4 below. 3. Optional: Install the rain guard over the insect guard to prevent rainwater from leaking into the exhaust hose. a. Insert the three projections on each rain guard into the holes in the insect guard. Side “A” should be at the top, as indicated in the diagram below.
b. Insert the insect guard firmly to ensure that the four projections fit into the holes of the window panel. Make sure that Side A is on the top. Double-hung sash window Sliding sash window Projection "A" Window panel Window panel "A" Projection 4. Slide the Exhaust Cover into the grooves of the Window Panel.
5.Installing the Window Panel(s) This window installation kit comes with 3 panels to adjust to your exact window size. You may not need to use all three panels. To begin, please refer to the guide below: ● If your window is less than 28 inches long you only need the window panel. You may need to saw off part of the window panel if your window is smaller than the window panel length. ● If your window is 28 to 46 inches long, you will need the window and adjustment panel.
a. Find the adjustment panel (with two grooves on each end), and a Fixed Clip and Mounting Plate. b. Insert the fixed clip into the groove of the adjustment panel. c. Slide the fixed clip into the groove of the window panel and slide the fixed clip until there is no gap between the two panels. d. Screw the mounting plate into the fixed clip to secure the panels together once it is at the length of your window. fixed clip mounting plate e.
6. Insert the window panel into the window sill and close the window securely against the Window panel. 7. Stuff Foam Seal A (non adhesive) between the glass and the window to prevent air and insects from getting into the room. Foam Seal A 8. Optional: Attach a bracket to the window frame with a screw to prevent any gaps from opening up.
Installing the Exhaust Hose Please note that the exhaust hose is REQUIRED to use for this portable air conditioner. This TOSOT portable air conditioner (like all air conditioners) must produce heat as a byproduct of producing cool air. If you don’t connect the exhaust hose your unit will exhaust this hot air into the room you are trying to cool. That won’t work very well. 1) Twist the Joint and Rear Clip clockwise onto the exhaust hose.
Tips: under 51 inches In order to improve the cooling efficiency of your air conditioner, the exhaust hose should be as short and direct as possible. Our suggested configuration is shown below. about 24 inches Removing Collected Water TOSOT portable air conditioner comes with an auto-evaporation system.The unit automatically evaporates condensation. There is no need to empty the water except in humid conditions.
Bottom drainage port Continuous Drainage Water can be drained into a floor drain by attaching a drain hose (included) to the continuous drain port. 1. Remove the continuous drain cap by turning it counter clockwise, then remove the rubber plug from the spout.
2. Screw the drain connector(included) into the spout by turning clockwise. 2. Insert the drain hose into the drain connector. Note: When using the continuous drainage option make sure that the air conditioner is located on a flat, level surface and that the drain hose is directed downwards and clear of any obstructions. Placing the air conditioner on an uneven surface may result in the chassis filling with water until the H8 malfunction code is displayed.
Installing the Power Cord Hooks Attach the two power cord hooks on the back of the unit using the included screws and wrap the power cord around the power cord hooks when not in use.
Cleaning and Maintenance Precautions ● Before cleaning the air conditioner, please turn off the unit and disconnect power. Otherwise, it may cause electric shock. ● Do not wash the air conditioner with water. Otherwise, it may cause electric shock. ● Do not use volatile liquid (such as thinner or gas) to clean the air conditioner. Otherwise, it may damage the appearance of the air conditioner.
3. Reinstall the filter After the filter has dried completely, reinstall back into the air conditioner. Note: ● Clean the filter at least every three months. ● Do not touch the metal fins in the air conditioner after removing the filter as they may cause personal injury. ● Do not attempt to dry the filter with a hairdryer or other heating elements as this may deform or ignite the filter. ● Do not operate the air conditioner if the air filter is missing. Maintenance Checklists Offseason checklist 1.
Troubleshooting Issues Air conditioner can't operate Poor cooling Air conditioner can't receive signals from remote control or remote control is not sensible. Self check Possible solutions Whether the unit is restarted up after stopping immediately? The unit is experiencing the 3-Minute Compressor Protection. Wait for 3min, and then turn on the unit again. For a detailed explanation, please refer to the answers below the diagram. Is plug loose? Reinsert the plug.
Issues Self check Possible solutions Is the unit in auto mode? Temp cannot be adjusted in auto mode Your desired temperature exceeds the AC range Temp set range is 61-86°F Air blowing from the air conditioner has a weird smell Check if the source of the odor is somewhere in the room Remove the source of the odor and clean the filter Abnormal sound during operation, such as water flowing Has the unit just been turned on or off? The flowing water sound is the refrigerant inside the air conditioner
Malfunction Codes Error code Possible causes F0 Refrigerant leakage F1 Ambient temperature sensor malfunction F2 Evaporator temperature sensor malfunction F4 Exhaust hose temperature sensor malfunction H3, E8 H8 Trouble shooting Please contact the manufacture for help. Overload malfunction 1. Check if the unit is under a high-temperature and highhumidity environment; restart the unit after the ambient temperature drops to 95°F (35°C) below. 2.
Warranty & Customer Support Warranty Information 1. 1-Year warranty: TOSOT Portable Air Conditioner comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing and material defects. Please visit https://tosotdirect.com/warranty for more details. 2. Additional 6-Month warranty extension: You can get a 6-month warranty extension by registering your new product at www.tosotdirect.com/extend. Customer Support Questions? We are here to help support@tosotdirect.com www.tosotdirect.