Installation Guide

305mm
138mm
290mm
43mm
380mm
185mm
565mm
60 mm±
10mm
215mm±
10mm
235mm±10mm
(Seat surface height)
For water supply from the floor
For water supply from the wall
For floor water supply specification
For wall water supply specification
[USA, Canada]
[Asia, Oceania, the Middle East, Korea, Macau]
(
8
-
4/8”
)
290mm
43mm
(
1
-
6/8”
)
(
9
-
2/8”
)
(
11
-
3/8”
)
(
7
-
2/8”
)
(
17
-
3/8”
)
440mm
140mm
±10mm
(
15
-
6/8”
)
(
23”
)
400mm
585mm
185mm
(
2
-
3/8”
)
60 mm±10mm
215mm±10mm
235mm±10mm
305mm
(
12”
)
138mm
(
5-3/8
)
9
Product Diagram (installation complete) image
468mm
701mm
1171mm
667mm
820mm (toilet bowl end 810mm)
140mm±10mm
820mm(toilet bowl end 810mm)
(32-2/8”
(
toilet bowl end 31-7/8”
)
)
468mm
(
18
-
3/8”
)
701mm
(
27
-
5/8”
)
667mm
(
26
-
2/8”
)
(
5
-
4/8”
)
(
46
-
7/8”
)
1191mm
8
EN
1.2m (3.94ft)
5.0m (16.40ft)
220
-
240V 835
-
845W 1445
-
1458W
120V1.2m (3.94ft)
1.8m (5.91ft) 220V 835W 1445W
Make sure that dirt from the silicone-based seal material does not adhere within the toilet bowl.
Secure the space required for toilet installation and at the same time, check door opening/closing for possible interference.
Turn on the electricity and water supply for the product only after all other installation work is complete.
Do not damage the connection components on the water supply hose.
The water supply pressure ranges from 0.05 MPa(7.25PSI) <dynamic, 10 L/min(2.6gal/min) or more> - 0.75 MPa(108.75PSI)<static>
.
Use the unit within the said pressure range. If the water supply pressure is low, toilet bowl cleaning may not be performed.
The temperature of the water supply should be within a range of 0 to 35°C(32-95
°F
). Make sure the temperature is within this range
.
Working ambient temperature is within the range of 0 to 40°C(32-104
°F
). Make sure the temperature is within this range.
Prepare an outlet position in advance that conforms to the regulations in your country.
If there is a gap between the discharge pipe and floor, fill it with mold-resistant silicone-based seal material (Mediseal).
Doing otherwise may cause water to leak downstairs.
* Before installing appliances, be sure to completely wash out any dirt, sand, etc. from inside the water supply pipe.
* Because a water flow test is conducted on each product at the factory, water may remain inside the product.
This water does not indicate a problem with the product.
Make sure before installation that the water supply source and water drain pipe are in the specified positions according to the
diagram.
Precautions before installation
The power plug (A-3) shape, power cord length, voltage, rated power consumption and maximum power consumption vary
depending on the version of the product. Check the appropriate type in the table below, and then wire and install the product
correctly.
Power plug blade shape Power cord length Voltage
Rated
power consumption
Maximum
power consumption
1297W 1453W
Tubo de descarga de PVC
Water supply Rc 1/2
Water supply Rc 1/2
(8
-
4/8”)
(5
-
4/8”)
(9
-
2/8”)
235mm±10mm
215mm±10mm
140mm±10mm
(2
-
3/8”)
60mm±10mm
(12”)
305mm±10mm