Installation Guide

3
ENGLISH
INSTALLATION PROCEDURE
In order for your new TOTO toilet to t correctly, please check the following dimensions:
1) Distance between nished wall and the center of the oor drain,
“RI”, must be 12” (305mm).
2) Water supply should be approximately 10” to 12” to the left (facing
the bowl) from the center line of closet ange, and approximately
6” above the nished oor.
Supply
Valve
Finished Wall
"RI"
C/L
Closet
Flange
Before Installation (continued)
1) Place the Modular Rough-In so that the baseline and the center line of the closet ange line up. Mark the screw locations for the Modular
Rough-In. Drill holes at the marked locations per the installation type below. In the case of tile or concrete oor installation, use the
provided plastic anchors.
2) Clean any debris out of the closet ange, then install the mounting bolts into the slot of
the ange head down with the threaded shank of the bolt pointed upward as shown (Ill.
1). Slide each bolt until the end of slot.
3) Turn the Modular Rough-In upside down. Firmly press a new wax seal onto the circular
recess around the outlet opening. Turn the Modular Rough-In upright and lower it onto
the position over the closet ange. With the unit properly aligned, press down rmly to
set the wax seal.
CA UTION: Do not move the Modular Rough-In afterwax seal is set.
Ill. 1
4) Install a washer and nut on the T-bolt to secure the r Modular Rough-In to the ange (see
Ill. 2). Nut should be tightened 1/2 turn after hand-tightening. For the Modular Rough-
In, secure the back side to the oor using the provided screws until level. DO NOT USE
EXCESSIVE FORCE.
CAUTION
To prevent water and odor leakage, please ensure that the wax seal is
tted properly between the Socket or Modular Rough-In and the ange.
Do not overtighten the nuts, as damage to the plastic parts may result.
For wood oor installation:
• 3/32” for Modular Rough-In
• 11⁄64” for Mounting Blocks
For concrete/tile installation:
• 9 ⁄32” for Modular Rough-In using green anchors
• 1 1⁄32” for Mounting Block using white anchors
With the location properly marked, drill holes.
5) To install the mounting block, follow the instructions below:
With the modular Rough-In installed, slide the toilet bowl in the Modular Rough-In by
aligning the toilet bowl horn with the Modular Rough-In inlet. (see Ill.4)
Make sure the toilet bowl is aligned properly before marking the center line of the
installation hole on both sides of the bowl and center front bowl. (see Ill. 5).
Remove the bowl and set aside, mark the location of the mounting block following the
measurement found in “Before Installation”. Install the mounting block using the screws
and washers provided. (see Ill. 6).
Ill. 2
Wax Ring
not included
Ill. 3
12" (305 mm)
Ill. 4
6” (152mm)
C/L
2"
(51mm)
Toilet Footprint
2"
(51mm)
C/L
6-3/8"
(160mm)
10-1/2”
(267mm)
10-1/2”
(267mm)
Base Line
Center lines of the
installation hole
Ill. 5
Ill. 6
Center lines of the
installation hole
2"
[51mm]
Center lines of
Mounting Block
Toilet
Outline