Specification Sheet

SPECIFICATIONS
• Water Use 1.0 GPF/3.8LPF
• Flush System Tornado Flush
®
• Min. Water Pressure 8 psi (flowing)
• Water Surface 6-7/8" x 9-3/4"
• Trap Diameter 2-1/8"
• Rough-in 12"
• Trap Seal 2-1/8"
• Warranty One Year Limited Warranty
• Material Vitreous china
• Shipping Weight CST614CUFGT20 110lbs
SW584T20 13.5lbs.
• Shipping Dimensions CST614CUFGT20
32"L x 20"W x 17-3/4" H
1
x
28-3/4" H
2
SW584T20
23"X 19-1/4" X 5-1/2"
• See Spec sheet SW584T20 for Washlet details
MW614584CUFG
Carlyle
®
II 1G
®
/ Washlet
®
+ S350e One-Piece Toilet - 1.0 GPF
SS-01137 v.03
Ph: (888) 295-8134 | Fax: (800) 699-4889 | www.totousa.com | © TOTO USA
INSTALLATION NOTES
Back-to-Back Toilet Installations:
TOTO recommends the use of a nationally listed,
double sanitary tee-wye only, in vertical waste stacks,
in accordance with the stipulations noted in the
majority of nationally recognized plumbing codes.
These dimensions and specifications are subject to change without notice
Double Sanitary Tee / Sanitary CrossDouble Combination Wye / 1/8 Bend
YES NO
Important Note:
Back-to-Back Toilet Installations:
TOTO USA, Inc. recommends the use
of a nationally listed, double sanitary
tee-wye only, in vertical waste stacks,
in accordance with the stipulations noted
in the majority of nationally recognized
plumbing codes.
!
* The 3-prong cord on the Washlet is on
the left side and is 3' long. The GFCI outlet
needs to have 120V, 10amps.
* GFCI Outlet
Min. 12” off floor
15-5/16"
(389mm)
18-7/8" (480mm)
(Round)
20-3/4" (529mm)
(Elongated)
3-15/16"
(100mm)
3/8"
(10mm)
1-5/8"
(42mm)
5-1/2"
(140mm)
7-1/16"
(180mm)
2-1/2"
(63mm)
7/8"
(22mm)
* The 3-prong cord on the Washlet is on
the left side and is 3' long. The GFCI outlet
needs to have 120V, 10amps.
* GFCI Outlet
Min. 12” off floor
15-5/16"
(389mm)
18-7/8" (480mm)
(Round)
20-3/4" (529mm)
(Elongated)
3-15/16"
(100mm)
3/8"
(10mm)
1-5/8"
(42mm)
5-1/2"
(140mm)
7-1/16"
(180mm)
2-1/2"
(63mm)
7/8"
(22mm)
To maintain adequate wall gap between the back of
the tank and wall, mount the floor flange at a nominal
12” rough-in distance.
Ultra-low high efficiency toilets require a system with
adequate supplemental flows from other water usage
fixtures and a 4” ID drainline with minimum 2% slope
and maximum linear runs of 60ft.