Spec Sheet
SPECIFICATIONS
SW2043R & SW2044
WASHLET
®
C200
# SS-01072 v.04
Ph: (888) 295-8134 | Fax: (800) 699-4889 | www.totousa.com | © TOTO USA
INSTALLATION NOTES
• For use with potable water only. Do not use with
recycled water.
• WASHLET C200 may not fit certain toilet bowl
designs.
• If possible, with your order, please include your
model number (from the underside of the tank lid).
• It is highly recommended to use a surge protector to
prevent damage in the event of a power surge.
These dimensions and specifications are subject to change without notice
*GCFI Outlet Min.
12" off floor
*The 3-prong cord on the Washlet is on the right side and is 4' long.
The GFCI outlet needs to have120V, 10amps.
5 1/2"
[140mm]
15 3/8"
[391mm]
20 7/8"
[531mm]
7 3/8"
[188mm]
5/16"
[8mm]
1 1/2"
[38mm]
Elongated
18 7/8"
[480mm]
Round
Power Rating
AC 120 V 60 Hz, 406W
Power Cord Length
3.94 ft (1.2 m)
Spray Volume
Rear Cleansing:
9.1 – 14.5 oz/min
Rear Soft Cleansing:
9.1 – 14.5 oz/min
Front Cleansing:
9.8 – 14.5 oz/min
Spray Features
Adjustable Surface Temp:
86 – 104 ºF (30 – 40 ºC)
Safety Device:
Thermal Fuse
Warm Air
Dryer Features
Adjustable Air Temp:
86 – 140 ºF (30 – 60 ºC)
Airflow Volume:
9.5 ft
3
/min
Safety Device:
Thermal Fuse
Heated Seat
Features
Adjustable Surface Temp:
82 – 97 ºF (28 – 36 ºC)
Safety Device:
Thermal Fuse
Water Supply
Pressure
Minimum:
7.25 PSI (Dynamic)
Maximum:
108.75 PSI (Static)
Ambient Temp.
32 – 104 ºF (0 – 40 ºC)
Warranty
One Year Limited
Warranty
Shipping Weight
C200 Elongated:
16 lbs
C200 Round:
16 lbs
Shipping
Dimensions
C200 Elongated -
23 ½” x 19” x 9”
C200 Round -
21 ½” x 19” x 9”
5 1/2"
[140mm]
15 3/8"
[390mm]
20 7/8"
[531mm]
22 3/4"
[579mm]
5/16"
[8mm]
1 1/2"
[38mm]
11 13/16"
[300mm]
7 7/8"
[200mm]
7 7/16"
[188mm]
18 7/8"
[480mm]
19 1/4"
[490mm]
9 13/16"
[250mm]
11"
[280mm]
SW2044
SW2043
SW2043R
SW2044
SW2043
SW2043R
20 3/4"
[528mm]
21 1/8"
[538mm]
SW2044
SW2043
SW2043R
*GCFI Outlet Min.
12" off floor
*The 3-prong cord on the Washlet is on the right side and is 4' long.
The GFCI outlet needs to have120V, 10amps.
5 1/2"
[140mm]
15 3/8"
[390mm]
20 7/8"
[531mm]
22 3/4"
[579mm]
5/16"
[8mm]
1 1/2"
[38mm]
11 13/16"
[300mm]
7 7/8"
[200mm]
7 7/16"
[188mm]
19 1/4"
[490mm]
11"
[280mm]
SW2044
SW2043R
SW2044
SW2043R
21 1/8"
[538mm]
SW2044
SW2043R
*GCFI Outlet Min.
12" off floor
*The 3-prong cord on the Washlet is on the right side and is 4' long.
The GFCI outlet needs to have120V, 10amps.
5 1/2"
[140mm]
15 3/8"
[390mm]
20 7/8"
[531mm]
22 3/4"
[579mm]
5/16"
[8mm]
1 1/2"
[38mm]
11 13/16"
[300mm]
7 7/8"
[200mm]
7 7/16"
[188mm]
19 1/4"
[490mm]
11"
[280mm]
SW2044
SW2043R
SW2044
SW2043R
21 1/8"
[538mm]
SW2044
SW2043R
*GCFI Outlet Min.
12" off floor
*The 3-prong cord on the Washlet is on the right side and is 4' long.
The GFCI outlet needs to have120V, 10amps.
5 1/2"
[140mm]
15 3/8"
[390mm]
20 7/8"
[531mm]
22 3/4"
[579mm]
5/16"
[8mm]
1 1/2"
[38mm]
11 13/16"
[300mm]
7 7/8"
[200mm]
7 7/16"
[188mm]
18 7/8"
[480mm]
19 1/4"
[490mm]
9 13/16"
[250mm]
11"
[280mm]
SW2044
SW2043
SW2043R
SW2044
SW2043
SW2043R
20 3/4"
[528mm]
21 1/8"
[538mm]
SW2044
SW2043
SW2043R
*GCFI Outlet Min.
12" off floor
*The 3-prong cord on the Washlet is on the right side and is 4' long.
The GFCI outlet needs to have120V, 10amps.