Installation Guide

Backup
Battery
Connector
2. Install the mounting bracket using the rubber washer, brass washer, and both brass nuts
on back side of the installation surface. Install the included set screw (for sheet metal
installation) or 30 mm machine screw (for drywall installations).
3.
Pass the hose and sensor cord through the mounting bracket, slide the spout base over the
mounting bracket and tighten the set screw to
secure the spout to the mounting bracket.
Set Screw
(Sheet metal) or
Machine Screw
(Drywall/ Hollow
Wall)
Rubber Washer
Brass Washer
Nuts (2)
ill. 9
Plywood
(not required for sheet
metal installation)
M5x30
Machine
Screw
and
Wall
Anchor
ill. 10
Set Screw
Mounting
Bracket
M5 Set
Screw
1x6 or Plywood
Bracing
Set Screw
Sheetmetal InstallationDrywall Installation
Mounting
Bracket
Thin Wall
(Sheet
Metal
Surface)
Drywall
6
ENGLISH
INSTALLATION PROCEDURE
1.
If the spout connecting hose is too long, cut it to the appropriate length, making sure the
end is square.
2.
Push the spout connecting hose onto the outlet barb of the controller and secure it with
the hose clamp (see ill. 1). Make sure that the hose clamp is placed fully against the
controller.
NOTE:
If you need to remove the hose,
you must use pliers to slide the
clamp up the hose, then use a
flathead screwdriver to carefully
pry the hose from the barb.
3.
IMPORTANT!
The faucet will begin an automatic sensing range adjustment immediately after the
sensor connector is plugged into the controller. Do not place your hands or other
objects in front of the sensor.This process may take up to 20 seconds to complete.
If the sensor light continues to flash for more than 20
seconds, the spout direction will need to be readjusted
for proper operation. If adjustment is necessary, you
must do it within 10 minutes of the adjustment process
will end. To restart the process, unplug the sensor
connector for 10 seconds, then reconnect it (see ill. 3)
4. Double-check all connections, then reinstall the controller cover, securing it wit eht h
WARNING: Draw the sensor cord from the bottom of the controller while installing the
controller cover to ensure that the cord is not pinched.
Connect the Spout to the Controller
Hose
Clamp
Clamp fush
with
controller
ill. 1
Spout
Connecting
Hose
ill. 3
Sensor
Light
Sensor
ill. 2
Sensor
Connector
screws.
Make sure there are no obstructions between the sensor and the basin, then connect
the spout sensor connector to the controller. (see ill. 2)
If you haven't connected the backup battery, connect the backup battery connector
to the controller. It will take at least 5 minutes after connecting the backup
battery for the electronics to initalize. This is a normal part of startup.