Installation Sheet

ENGLISH
When the inlet strainer is clogged, the flow rate will decrease. Decreased flow rate can
lead to insufficient power generation, which will deplete the backup battery prematurely.
To clean the strainer (see ill. 1):
1. Turn the water off at the stop valves.
2. Remove controller cover and then remove
quick fastener.
3. Remove contorller.
4. Remove strainer and clean it with a brush.
5. Reinstall the clean strainer
IMPORTANT!
Be sure to install flow regulator in the correct
orientation as shown. Otherwise, product does
not function properly.
6. Reinstall the controller into the adaper until
fully seated, and secure it with the quick
fastener.
7. Reinstall cover, securing it with the screws
8. Open angle stop and check all
connections.
To clean the nozzle (see ill. 2):
1. Remove the nozzle from the spout
with the supplied tool.
2. Clean the nozzle with a soft brush
to remove any dirt from the screen.
3. Re-install the nozzle in the spout.
Power supply Hydropower Generation (self-powering power supply)
Sensor Detection Range 5-1/8”~ 7-7/8” (130~200mm)
Sensor is self-adjusting.
Water Supply Pressure
Minimum required water pressure: 15 psi (100 kPa) (Flowing)
Maximum water pressure: 80 psi (551 kPa)
Water Supply Connection G1/2 compatible with ½ NPSM
39 ~ 110°F (4 ~ 43.3°C)
Inlet Temperature range
Ambient Temperature 32~104°F (0~40°C)
Humidity Max. 90% RH
0.09 gpc (0.36 Lpc) *
0.18 gpc (0.67 Lpc) *
0.19 gpc (0.72 Lpc) *
Flow Rate*
Duration Time of Water
Discharge*
10 seconds*
20 seconds*
* Refer to specification sheet or consult with a TOTO Rep. for model numbers, flow rate and
water discharge duration of each model.
SPECIFICATIONS
Open
Close
Spout
Nozzle
Key
ill. 2
Spout
Nozzle
Brush
ill. 1
Strainer
Flow
Regulator
Quick
Fastener
PERIODIC MAINTENANCE
Cleaning the Inlet Strainer and Nozzle