ENGLISH
PERIODIC MAINTENANCE
Please check the piping to your EcoPower Flush Valve at least once a month
to avoid risk of property damage.
USING THE FLUSH VALVE
Infrared Sensor Flushing
Flushing Every 12/24 hours
Manual Flushing Button
The infrared sensor detects a user
of the toilet or within 2 ft (600mm)
of the urinal.
When the user stays in place for at
least 6 seconds before departure,
the controller signals the operating
unit to trip the Flush Valve after 3
seconds delay for toilets and no
delay for urinals.
Use the manual flush switch for
maintenance or emergencies.
NOTE TO THE INSTALLER
After the Flush Valve unit has been installed correctly, please explain to your customer how to
use it and tell them to observe the following instructions:
1. Do not put any object in front of the sensor window which could obstruct the sensor,
causing it to malfunction.
2. In case of any trouble, consult the troubleshooting section on p.16. If you lack the
necessary skills required or have difficulty following the directions for installation,
maintenance, repairs, troubleshooting or adjustments of the product, do not proceed
without help from a qualified person to assist you.
When the fixture is not used for 24 hours for toilet or 12 hours for urinal the protection
timer commands the system to flush in order to maintain the trap seal.
CARE & CLEANING
IMPORTANT! Do not scratch the sensor or faceplate when cleaning.
Avoid using any cleaning materials that may scratch the surface.
Never use polishing powder, detergent that includes coarse particles, thinners,
benzene, acids, alkaline detergents, or nylon scrub brushes.
To safely clean the surface, wipe it using a dampened soft cloth with diluted
dishwashing detergent and dry it with another soft cloth. If this does not adequately
clean the surface, wipe the area with a neutral detergent and wet cloth.