Specification Sheet
TET3GA
EcoPower
®
Toilet Flush Valve, 1.6 gpf
#SS-01167, v.01
Ph: (888) 295-8134 | Fax: (800) 699-4889 | www.totousa.com | © TOTO USA
These dimensions and specifications are subject to change without notice
SPECIFICATIONS INSTALLATION NOTES
• Material Bronze casting
• Power supply EcoPower
• Sensor detection time Factory setting at six
(6) seconds minimum
• Sensor detection range Self-adjusting to
environment
• Discharge quantity Preset to 1.6 gpf/
6.0 lpf
• Operating temperature 32°-104°F (0°-40°C)
• Water supply pressure 15 psi - 125 psi*
• Water supply connection 1" NPT
• Warranty Three year limited
4 x Ø5/16" (Ø8mm) hole
Left water supply pipe
1”NPT (toilet), 3/4” (urinal)
Right water supply pipe
1”NPT (toilet), 3/4” (urinal)
Toilet top spud
Ø2-3/16” (Ø56 mm) hole
Urinal back spud
Ø1-5/16” (Ø33 mm) hole
Toilet back spud
Ø2-3/16” (Ø55 mm) hole
X”
1-1/4” (31 mm)
CL of sensor
** 3-11/16”
(94mm)
11” (279mm)
16” (406mm)
** 3-11/16”
(94 mm)
* X”, ‡ = At least 5” clearance from sensor to tip of toilet seat up position or
to top of grab bar is required to avoid false detection.
** Opening in wall
4-3/4”
(120mm)
3-11/16”
(94mm)
4-3/8”
(110mm)
3-11/16”
(94mm)
4-3/8”
(110mm)
3-11/16”
(94mm)
4-3/4”
120mm)
3-11/16”
(94mm)
1-1/4”
(31mm)
4-3/4” ± 1/2”
(120 ± 13mm)
Urinal top spud
Ø1-5/16” (Ø33mm) hole
DIAGRAM
For commercial applications only.
Warning: Failure to properly adjust angle stop to
the appropriate level can potentially cause property
damage.
For detailed installation instructions, please refer to
the installation manual.
Max flow rate to be used with
TET3GA___________: 1.6 gpf
Confirm with local codes and standards for floor drain
requirement. Adjust control stop for proper flow rate
to the fixture.
The recommended installation for the flush valve is
to have a 7" (178mm) minimum space in wall with a
minimum 12" x 12" access panel or walk-in chase (for
service and maintenance purposes). Do not place grab
bars in front of sensor for ADA stalls.
*Water pressures over 80 psi are not recommended for most plumbing
fixtures. Check your local plumbing code for details.
33-1/2"
(850mm)
15°
Max 19-11/16”
(Max 500mm)