Installation Sheet

BEFORE INSTALLATION
WARNINGS
Important: Plumbing installation must be in accordance with applicable codes and
regulations. Water supply lines must be sized to provide an adequate volume of water for
each fixture. Flush all waterlines prior to operation.
1. Prior to installing your Flush Valve, install the items listed below:
Bowl fixture/Urinal fixture
Drain line
Water supply line
The supply piping to these devices must be securely anchored to the building structure to
prevent the installed device moving during use. Prevent marring to the exposed surface
during installation.
Except for TET6GA and TET6LA, install the Flush Valve so the control stop is no less than
11-1/8” (282mm) above the top of the bowl/urinal. For TET6GA andTET6LA, install the Flush
Valve such the control stop is 27” (685.8mm) above the bowl/urinal. see local codes for
special requirements.
2. Avoid damaging the surface of the infrared sensor.
3. For Toilet Flush Valve:
The toilet Flush Valve may not function if toilet seat or lid cover are left upright and block the
sensor.
For Urinal Flush Valve:
The urinal Flush Valve is designed for optimal performance with a washout urinal, but a
siphon jet urinal may be substituted. Blowout urinals are not recommended.
4. The detection range of the infrared sensor is shown on p.15.
To prevent valve malfunction, do not install a handrail or any other object within the detection
range of the sensor. Do not install the Flush Valve where sensor faces a mirror, stainless steel
wall, other highly reflective surfaces or another infrared sensor.
Please read and adhere to these notes. Failure to do so could result in personal injury and/or
property damage.
Never splash water on the controller. The EcoPower Flush Valve is an electric appliance.
Risk of product malfunction.
Do not strike or kick the EcoPower Flush Valve. Risk of product malfunction or water
leakage.
Do not use the EcoPower Flush Valve at temperatures exceeding what local codes or
product specification allow. Risk of product malfunction.
Do not place an item in a room with high humidity such as shower area or sauna. Risk of
product malfunction.
Never attempt to disassemble, reassemble, repair or modify the EcoPower Flush Valve
unless you are a professional. Risk of product malfunction and electric shock.
ENGLISH
6