Installation Procedure (continued)
7. Turn on the water and let it run for a few
minutes. Adjust the valve stem until the water
temperature is 104°F. Turn off the water.
Place the handle on the valve stem with the
button at the top. Turn on the water and check
that the temperature is still 104°F.
Turn the handle counterclockwise without
pressing the button until the handle stops.
Check that the temperature is around 108°F.
Press the button and turn the handle until it
stops. Check that the temperature is around
120°F.
Turn the handle back to 104°F and check the
temperature again. If the temperature is
correct, secure the handle with the set screw.
Set Screw
Hex Key