TECHNICAL GUIDE GYPSUM BOARD
ToughRock® Gypsum Products ToughRock® Product Overview ToughRock® Gypsum Boards include paper-faced drywall panels for a wide range of interior and exterior applications, including fire-rated wall and ceiling assemblies, exterior sheathing, soffit and more. The standard-weight, 1/2” panel has been enhanced and now carries a fire rating with the introduction of ToughRock® Fireguard 45® Gypsum Board.
ToughRock® Gypsum Products ToughRock® Interior Gypsum Board Calculator Determine the wall and ceiling areas: Width of the room x Length of the room = Ceiling area (Width + Length) x 2 x Height of the room = Wall area For example, a 12’ x 16’ x 8’ room has a wall/ceiling area of 640 sq. ft. Ceiling area: 12 x 16 = 192 Wall area: (12 + 16) x 2 x 8 = 448; 192 + 448 = 640.
ToughRock® Gypsum Products Interior Gypsum Board Installation ToughRock® Gypsum Board products should be installed according to the most current versions of Gypsum Association GA-216 “Application and Finishing of Gypsum Panel Products” and ASTM C840 “Standard Specification for Application and Finishing of Gypsum Board for Non-Fire Rated Construction.” Walls Several methods are used to attach gypsum boards to the framing including fasteners, adhesives, and fasteners and adhesives together.
ToughRock® Gypsum Products Finishing Interior Gypsum Board Joints/Levels of Finish Please refer to the Recommended Levels of Gypsum Board Finish, Gypsum Association publication GA-214, for recommendations of various levels of finish of gypsum board surfaces prior to the application of specific types of final decoration.
ToughRock® Gypsum Products ToughRock® Gypsum Board Physical Properties Properties ASTM Test Method 1/4” ToughRock® Gypsum Board 3/8” ToughRock® Gypsum Board 1/2” ToughRock® Fireguard 45® Gypsum Board 1/2” ToughRock® Lite-Weight Gypsum Board Thickness2, nominal inches (mm) ± 1/64” (0.4 mm) C473 B 1/4 (6.4) 3/8 (9.5) 1/2 (12.7) 1/2 (12.7) Width2, nominal inches (mm) - 3/32” (2.4 mm) 48 (1219) 48 (1219) 48 (1219) 54 (1372) 48 (1219) 54 (1372) Length, standard feet (mm) ± 1/4” (6.
ToughRock® Gypsum Products ToughRock® Fireguard X® Gypsum Board Physical Properties Properties ASTM Test Method 5/8” ToughRock® Lite-Weight Fire-Rated Gypsum Board 5/8” ToughRock® Fireguard X® Gypsum Board 1/2” ToughRock® Fireguard C® Gypsum Board 5/8” ToughRock® Fireguard C® Gypsum Board Thickness2, nominal inches (mm) ± 1/64” (0.4 mm) Width2, nominal inches (mm) - 3/32” (2.4 mm) Length, standard feet (mm) ± 1/4” (6.4 mm) Edges2 C473 B 5/8 (15.9) 5/8 (15.9) 1/2 (12.7) 5/8 (15.
ToughRock® Gypsum Products ToughRock® Mold-Guard™ Gypsum Board Physical Properties Properties ASTM Test Method 1/2” ToughRock® Mold-Guard™ Gypsum Board 5/8” ToughRock® Fireguard X® Mold-Guard™ Gypsum Board 5/8” ToughRock® Fireguard X® MoldGuard™ Abuse-Resistant Gypsum Board Thickness2, nominal inches (mm) ± 1/64” (0.4 mm) C473 B 1/2 (12.7) 5/8 (15.9) 5/8 (15.9) Width2, nominal inches (mm) - 3/32” (2.4 mm) 48 (1219) 48 (1219) 54 (1372) 48 (1219) Length, standard feet (mm) ± 1/4” (6.
ToughRock® Gypsum Products ToughRock® Specialty Gypsum Board Physical Properties Properties ASTM Test Method 1/2” ToughRock® Span 24® Ceiling Board 1/2” ToughRock® Lite-Weight Veneer Plaster Base 5/8” ToughRock® Fireguard X® Veneer Plaster Base Thickness2, nominal inches (mm) ± 1/64” (0.4 mm) C473 B 1/2 (12.7) 1/2 (12.7) 5/8 (15.9) Width2, nominal inches (mm) - 3/32” (2.4 mm) 48 (1219) 48 (1219) 48 (1219) Length, standard feet (mm) ± 1/4” (6.
ToughRock® Gypsum Products Interior Gypsum Board Recommendations and Limitations for Use The following recommendations and limitations are important to ensure the proper use and benefits of ToughRock® Gypsum Board. Failure to strictly adhere to such recommendations and limitations may void the limited warranty provided by Georgia-Pacific Gypsum for such product. For additional details, please go to www.gpgypsum.com and select ToughRock Gypsum Board. ToughRock® Gypsum Board 1.
ToughRock® Gypsum Products ToughRock® Gypsum Sheathing ToughRock Gypsum Sheathing is recommended for use in residential or commercial buildings as a substrate that is covered by cladding such as vinyl or fiber cement siding, masonry veneer, or wire lath stucco. It is designed for direct mechanical attachment to wood or steel framing.
ToughRock® Gypsum Products Fastening and Framing Thickness Framing Spacing Panel Orientation 1/2” (12.7 mm) 24” (610 mm) o.c. max 5/8” (15.9 mm) 24” (610 mm) o.c. max2 2 Fastener Spacing – Wood Framing3 Fastener Spacing – Metal Framing3 Parallel or Perpendicular 8” (203 mm) o.c. field1 & perimeter 8” (203 mm) o.c. along framing Parallel2 or Perpendicular 8” (203 mm) o.c. field1 & perimeter 8” (203 mm) o.c.
ToughRock® Gypsum Products Wall Applications Installing Cladding over ToughRock® Gypsum Sheathing Most conventional exterior sidings and wall coverings—including wood, vinyl, composition, metal, stone, brick, wood shingles, shakes and plywood boards—may be applied over ToughRock Gypsum Sheathing. Consult your local building codes for water resistive barriers (WRB) requirements. A. B. C. D. E. F. ToughRock Gypsum Sheathing Insulation Framing Water-Resistive/Air Barrier Masonry Tie 2” (50 mm) Max.
ToughRock® Gypsum Products Sheathing Recommendations and Limitations for Use The following recommendations and limitations are important to ensure the proper use of ToughRock Gypsum Sheathing. Failure to strictly adhere to such recommendations and limitations may void the limited warranty provided by Georgia-Pacific Gypsum for such product. For additional details, please go to www.buildgp.com/warranties and select ToughRock Gypsum Board for warranty information.
ToughRock® Gypsum Products Soffit Applications, Fastening, Framing and Finishing ToughRock® Soffit Board is used for exterior soffits, covered walkways, porch and lanai ceilings, and drive-under garages. It has tapered edges for easy finishing. Thickness Framing Spacing Orientation Screw Spacing 5/8” (15.9 mm) 24” (610 mm) o.c. max Perpendicular 8” (203 mm) o.c. along framing Painted Ceilings and Soffits Finished Joints A. B. C. D. E.
ToughRock® Gypsum Products ToughRock® Exterior Gypsum Board Physical Properties Properties ASTM Test Method 1/2” (12.7 mm) 5/8” (15.9 mm) 5/8” (15.9 mm) ToughRock® Sheathing ToughRock® Fireguard X® ToughRock® Fireguard C® Sheathing Soffit Board Thickness2, nominal inches (mm) ± 1/64” (0.4 mm) C473 B 1/2 (12.7) ± 1/32 (0.8) 5/8 (15.9) ± 1/32 (0.8) 5/8 (15.9) ± 1/64 (0.4) Width2, nominal inches (mm) - 3/32” (2.4 mm) 48 (1219) 48 (1219) 48 (1219) Length, standard feet (mm) ± 1/4” (6.
ToughRock® Gypsum Products ToughRock® Shaftliner – Area Separation Wall As land costs and construction costs increase, more builders are constructing multi-family housing. Any time families share walls, there is a concern about safety and comfort. A fire started by a careless tenant can destroy the accumulations of a lifetime. The irritating noise of a neighbor can affect quality of life.
ToughRock® Gypsum Products Installation of 2” (51 mm) Area Separation Wall 1. Position 2” (51 mm) C-Track a minimum 3/4” (19 mm) from the framed wall of the adjacent unit. Fasten C-Track to foundation with fasteners spaced a maximum of 24” (610 mm) o.c. When specified, apply a minimum 1/4” (6 mm) bead of acoustical sealant under the C-Track to maximize acoustical privacy. Run the C-Track to the end of the foundation. In case of offset units, see 15 under Special Conditions. 2.
ToughRock® Gypsum Products Special Conditions 1. When an H-Stud does not align with the adjacent wood framing, insert blocking between wood framing members and attach breakaway clip to blocking using one 1-1/4” (32 mm) drywall screw and to the H-Stud using a minimum of one 3/8” (9 mm) minimum length pan head screw. 2. If gaps are present between back-to-back C-Tracks, caulk using appropriate fire caulking material. 3. When wall framing is spaced greater than 1” (25.
ToughRock® Gypsum Products System Assemblies – 2-Hour Ratings – Area Separation Walls 2-Hour Fire Rating Design Reference: UL U375, WHI GP/WA 120-03, cUL U375 59 STC Sound Trans. Test Reference: RAL TL 10-290 Two layers 1” (25.4 mm) ToughRock® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Min. 3/4” (19 mm) air space between liner boards and adjacent wood or metal framing. Sound Tested with 2” (51 mm) x 4” (102 mm) stud wall with 1/2” (12.
ToughRock® Gypsum Products System Assemblies – 2-Hour Ratings – Area Separation Walls 2-Hour Fire Rating Design Reference: GET 4/13/70, GA WP 7125 35-39 STC Sound Trans. Test Reference: KG 634 Approx. Weight: 9.5 psf (46 Kg/m2) Base layer 5/8” (15.9 mm) ToughRock® Fireguard® X Gypsum Board applied horizontally to one side only of 1 5/8” (41 mm) 18 mil (25 ga.), steel studs 24” (610 mm) o.c. with 1” (25.4 mm) Type S drywall screws 12” (305 mm) o.c. Second layer 5/8” (15.
ToughRock® Gypsum Products Details The following assemblies and details are for illustration purposes only. Please consult design authority and confirm code compliance. Georgia-Pacific Gypsum does not provide design services. A B C Nivel del suelo Ground Level Sótano de 2286-2438 mm Basement (7’6” – 8’) 7’6”- de 8’ altura (2286-2438 mm) High D Muro de concreto vertido Poured Concrete Wall A. Roof-Ceiling ©2 016 Ge org ia-P aci fic Gyp sum Parapet Cap B.
ToughRock® Gypsum Products Roof Sheathing Double C-Runner Track (back to back) ToughRock® Shaftliner Floor ToughRock® Fireguard 45® Gypsum Board Fire Blocking with ToughRock Shaftliner Gypsum Board (as required by local codes) 23’ (7010 mm) Walls up to 23’ (7010 mm) space clips a maximum of 10’ (3048 mm) o.c. Framing H-Stud 44’ (13411 mm) Walls up to 44’ (13411 mm) space clips a maximum of 5' (1524 mm) o.c.
ToughRock® Gypsum Products Protruding Exterior Wall ToughRock® Fireguard 45® Gypsum Board H-Stud Exterior Finish Flashing Caulking (as required) Cap ToughRock® Shaftliner C-Track n. 3/4” (19 mm) Air Space Interior Wall Framing Exterior Wall Framing Fire Blocking with ToughRock® Shaftliner or as required Roof Intersection with Parallel Roof Trusses 5/8” (15.
ToughRock® Gypsum Products Typical Roof Junction Detail Caulk (smoke-tight joint as 5/8” (15.9 mm) ToughRock® Fireguard X® Gypsum Board required by local codes) Tough/Rock® Shaftliner (as required by local codes) Roof Deck Roofing ToughRock® Fireguard 45® Gypsum Board H-Stud ASW Clip ToughRock® Shaftliner CAUTION: For product fire, safety and use information, go to buildgp.com/safetyinfo. For latest information and updates: 25 Technical Service Hotline 1.800.225.6119 or www.gpgypsum.
ToughRock® Gypsum Products Shaftwall/ Stairwell Systems ToughRock® Shaftliner is used as a component in a system used to enclose elevator shafts, construct fire rate stairwells, duct protection, air return systems, and horizontal membranes. Unlike heavy and expensive masonry construction in the building core, stairwell/shaftwall enclosures are lighter weight, maintenance-free, and go up quickly without construction delay during cold weather.
ToughRock® Gypsum Products Shaftliner/Stairwell Installation Instructions 1. Lay out per construction drawings. Secure J track as perimeter framing on floor and plumb to ceiling and sides. Attach with fasteners no more than 24” (610 mm) o.c. 2. Install the ToughRock® Shaftliner, cut 3/4” (19 mm) (or as required by fire test reference) less than the total height of the framed section. Plumb the board flush against the web of the J track and secure with 1-5/8” (41 mm) Type S screws 24” (610 mm) o.c.
ToughRock® Gypsum Products Fire-Rated Assemblies 2-Hour Fire Rating Design Reference: UL V493, cUL V493 45-49 STC Sound Trans. Test Reference: RAL TL 09-359 Approx. Weight: 8.5 psf (42 Kg/m2) One layer 1” (25.4 mm) x 24” (610 mm) ToughRock® Shaftliner inserted between 2-1/2” (64 mm) floor and ceiling runners with tab-flange section of 2-1/2” (64 mm) steel C-H, C-T, or I studs between panels. One layer 5/8” (15.9 mm) ToughRock® Fireguard® X gypsum board applied vertically to each side with 1” (25.
ToughRock® Gypsum Products Fire-Rated Assemblies 3-Hour Fire Rating Design Reference: WHI Design GP/WA 180-01 50-54 STC Sound Trans. Test Reference: RAL TL 09-360 Approx. Weight: 12 psf (59 Kg/m2) One layer 1” (25.4 mm) x 24” (610 mm) ToughRock® Shaftliner inserted between 2-1/2” (64 mm) floor and ceiling runners with tab-flange section of 2-1/2” (64 mm) steel C-H, C-T, or I studs between panels. Base layer 5/8” (15.9 mm) ToughRock® Fireguard® C Gypsum Board applied horizontally to studs with 1” (25.
ToughRock® Gypsum Products Door Frame Details There are numerous elevator door frame combinations and special conditions that cannot be detailed beyond general conditions in this catalog. The interface of the shaftwall system and elevator door frame should be addressed in the shop drawings of the elevator and/or frame manufacturer literature. A. B. C. D. E. F. G. H. I. J. K. L. C-T, C-H or I studs 24” (610 mm) o.c.
ToughRock® Gypsum Products Wall Frame Details A. Alternate to bending tabs: use 1-5/8” (41 mm) Type S screws at 24” (610 mm) o.c. B. Tabs in J track bent out at 24” (610 mm), alternate to using screws C. J track – 20 (33 mils) or 25 (18 mils) gauge D. Attached to J track prior to installation. E. Metal C stud or J track where span is over 24” (610 mm), alternate to using screws F. Spray-on fireproofing G. 1/2” (12.7 mm) ToughRock® Fireguard C® Gypsum Board or 5/8” (15.
ToughRock® Gypsum Products Rails/Chute/Beam Details A. 1” (25.4 mm) ToughRock® Shaftliner B. Additional attachment of 1” (25.4 mm) ToughRock Shaftliner, inside or outside item A C. 1/2” (12.7 mm) ToughRock® Fireguard C® Gypsum Board or 5/8” (15.9 mm) ToughRock® Fireguard X® Gypsum Board D. Typical call indicator box E. Spray-on fireproofing F. Fasteners 24” (610 mm) o.c. Call Box/Outlet Box/Mail Chute G. J track 4” (102 mm) minimum height behind box and screw attached H.
ToughRock® Gypsum Products HVAC Duct Detail Duct A. C-T, C-H or I Studs 24” (610 mm) o.c. B J track Headers with ends slotted to fit into shaftwall studs D B. J track A C. 1” (25.4 mm) ToughRock® Shaftliner B E C C C Attach to J track header with pan head screws C Shaftwall Studs D E Recommendations • Use a fastening plate to secure the J track whenever fasteners are closer than 4” (102 mm) to the end of the assembly.
ToughRock® Gypsum Products Fire Rating Information ToughRock® Fireguard X,® ToughRock® Fireguard X® Mold-Guard™ and ToughRock Fireguard C® Gypsum Board products have been classified by UL and included in numerous assembly designs listed by UL for hourly fire resistance ratings. Several ToughRock® Fireguard X® and ToughRock® Fireguard C® Gypsum Board products have also been classified by Underwriters Laboratories of Canada (ULC) for inclusion in fire resistance ratings.
High-Performance Gypsum Products from Georgia-Pacific DensDeck® Roof Board Fiberglass mat roof board used as the ideal thermal barrier and cover board to improve resistance to wind uplift, hail, foot traffic, fire and mold in a broad range of commercial roofing applications. Look for DensDeck Prime and DensDeck DuraGuard Roof Boards, too.