24
DOWNLINK
UPLINK
1 dB 2 dB 4 dB 8 dB 16 dB
Additive combination effects:
Switch 1 (1 dB) + Switch 2 (2 dB) = 3 dB attenuation
Switch 1 (1 dB) + Switch 2 (2 dB) + Switch 3 (4 dB) = 7 dB attenuation
Switch 1 (1 dB) + Switch 2 (2 dB) + Switch 3 (4 dB) + Switch 4 (8 dB) = 15 dB attenuation
Switch1(1dB)+Switch2(2dB)+Switch3(4dB)+Switch4(8dB)+Switch5(16dB) = 31 dB attenuation. A few
practical attenuation example:
Important Note: Turn ALL uplink attenuation DIP switches to ON and adjust them back one step at a time until uplink connectivity is made
with the Emergency Radio Tower.
Turning all switches OFF = 0 dB attenuation (booster is at full gain).
Turning ON switch #1 in a bank = 1 dB attenuation (booster maximum gain is reduced by 1 dB).
Turning ON switches #1, 3, and 5 in a bank = 1+4+16 dB attenuation = 21 dB attenuation. For example, in an 80 dB booster, the
selected channel is reduced to 59 dB (80 dB ‐21 dB).
Turning ON switches #1, 1, 4, and 5 in a bank = 1+8+16 dB attenuation = 25 dB attenuation. For example, in an 80 dB booster, the
selected channel is reduced to 55 dB (80 dB‐25 dB).
Note: When all the switches in a bank are turned on, the corresponding
RF link will be shut down. And the maximum attenuation is 25dB for
each link.
When the BDA is powered on, the green Power Light (3) should
illuminate.
If any of the bands are oscillating, the corresponding band lights (1
and/or 2) will flash red and that band will eventually shut down if
adjustments are not made.
Note: In general, the uplink and downlink DIP switches should be set
identically but this is not always the case.
12 4816
123 45
124816
12345
Switch 1 Switch 2 Switch 3 Switch 4 Switch 5
SILENCING
1
PS700
3
POWER
2
PS800
123 4 5 123 4 5 123 4 5
PS8 00-DL
1
2
4
8
16
PS-UL
1
2
4
8
16
PS7 00-DL
1
2
4
8
16