Business Networking Solution Installation Guide JetStream 8-Port Gigabit Smart PoE+Switch with 2 SFP Slots T1500G-10MPS
FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Safety Information • • • When product has power button, the power button is one of the way to shut off the product; when there is no power button, the only way to completely shut off power is to disconnect the product or the power adapter from the power source. Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us. Avoid water and wet locations.
Related Document This Installation Guide is also available in PDF on our website. To obtain the latest documentation and product information, please visit the official website: http://www.tp-link.com About this Installation Guide This Installation Guide describes the hardware characteristics, installation methods and the points that should be attended to during the installation. This Installation Guide is structured as follows: Chapter 1 Introduction.
Contents Chapter 1 Introduction———————————— 01 1.1 1.2 Product Overview............................................................01 Appearance........................................................................01 Chapter 2 Installation———————————— 05 2.1 Package Contents...........................................................05 2.3 Installation Tools...............................................................07 2.2 2.4 Safety Precautions...................................................
Smart PoE+ Switch Chapter 1 Introduction 1.1 Product Overview T1500G-10MPS is compliant with the IEEE802.3 Ethernet protocols. The switch is equipped with powerful management interface, via which system, port, network, VLAN and priority can be configured. They provide a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks.
Smart PoE+ Switch LEDs T1500G-10MPS has an LED mode switch button which is for switching the LED status indication. When the Speed LED is on, the port LED is indicating the data transmission status. When the PoE LED is on, the port LED is indicating the power supply status. By default, the Speed LED is on. Pressing the mode switch button, the Speed LED will turn off and the PoE LED will light up. Then the PoE LED will turn off after being on for 60 seconds and the Speed LED will light up again.
Smart PoE+ Switch When the PoE LED is on, the port LED is indicating the power supply status.
Smart PoE+ Switch ■■ Rear Panel The rear panel of T1500G-10MPS is shown as the following figure. Kensington Security Slot Power Socket Grounding Terminal Figure 1-2 Rear Panel of T1500G-10MPS Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen. Power Socket Connect the female connector of the power cord here, and the male connector to the AC (Alternating Current) power outlet.
Smart PoE+ Switch Chapter 2 Installation 2.1 Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Switch One Power Cord This Installation Guide Business Networking Solution Installation Guide One Resource CD 2.2 Two mounting brackets, eight screws and four feet Safety Precautions To avoid any device damage and bodily injury caused by improper use, please observe the following rules.
Smart PoE+ Switch Temperature/Humidity 40℃ 0℃ Please keep a proper temperature and humidity in the equipment room. Too high/ low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table.
Smart PoE+ Switch Lightening Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken. ■■ ■■ ■■ ■■ Ensure the rack and device are well earthed. Make sure the power socket has a good contact with the ground.
Smart PoE+ Switch 2.4 Product Installation ■■ Desktop Installation To install the device on the desktop, please follow the steps: 1. Set the device on a flat surface strong enough to support the entire weight of the device with all fittings. 2. Remove the adhesive backing papers from the rubber feet. 3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device.
Smart PoE+ Switch 3. After the brackets are attached to the device, use suitable screws (not provided) to secure the brackets to the rack, as illustrated in the following figure. Rack Figure 2-3 Rack Installation Caution: Please set 5 to 10cm gaps around the device for air circulation. Please avoid any heavy thing placed on the device. Please mount devices in sequence from the bottom to top of the rack and ensure a certain clearance between devices for the purpose of heat dissipation.
Smart PoE+ Switch Chapter 3 Lightning Protection 3.1 Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices. Note: It 's not recommended using Ethernet cables outdoors. When cabling outdoors, please use a signal lightning arrester.
Smart PoE+ Switch ■■ Requirements for Cabling Indoors When cabling indoors, keep a certain distance away from the devices that may cause high-frequency interferences, such as down-conductor cable, powerline, power transformer and electromotor. ■■ ■■ The main cable should be paved in the metal raceway of the access shaft. When cabling, keep the loop area formed by the cable itself as small as possible. Requirements for the distance between Ethernet cable and other pipelines are shown in the table.
Smart PoE+ Switch Cable 2 to 5kVA powerline >5kVA powerline Pave Way Parallel cabling One is in the grounded metal raceway or metal pipe The both are in the grounded metal raceway or metal pipe 300 150 80 Parallel cabling 600 The both are in the grounded metal raceway or metal pipe 150 One is in the grounded metal raceway or metal pipe Device Min Distance (m) Transformer room 2.00 Air-conditioner room 2.00 Switch case Elevator tower 3.2 Min Parallel Length (mm) 300 1.00 2.
Smart PoE+ Switch Figure 3-1 Connecting to the Ground Note: The figure is to illustrate the application and principle. The power plug you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above. If you intend to connect the device to the ground via the PE (Protecting Earth) cable of AC power cord, please make sure the PE (Protecting Earth) cable in the electrical outlet is well grounded in advance.
Smart PoE+ Switch Note: The grounding bar and the ground cable are not provided with our product. If needed, please self purchase them. Equipotential Bonding Equipotential Bonding is the practice of intentionally electrically connecting all earthed systems to the same grounding grid or connecting the grounding grids of all the earthed systems together through the ground or overground metal so as to create an earthed equipotential zone.
Smart PoE+ Switch Power lightning arrester is used for limiting the voltage surge due to a lightning. If an outdoor AC power cord should be directly connected to the device, please use a power lightning arrester. Note: Power lightning arrester is not provided with our product. If needed, please self purchase it. Signal lightning arrester is used to protect RJ45 ports of the device from lightning. When cabling outdoors, please install a signal lightning arrester before connecting the cable to the device.
Smart PoE+ Switch Chapter 4 Connection 4.1 Ethernet Port Connect a Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. RJ45 Port RJ45 Cable Figure 4-1 Connecting the RJ45 Port 4.2 Verify Installation After completing the installation, please verify the following items: ■■ ■■ ■■ ■■ 4.3 There are 5 to 10cm of clearance around the sides of the device for ventilation and the air flow is adequate.
Smart PoE+ Switch Note: The figure is to illustrate the application and principle. The power plug you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above. 4.4 Initialization After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically to ensure the device functions properly. During this time, its LED indicators will respond as follows: ■■ ■■ ■■ The PWR LED remains on.
Smart PoE+ Switch Appendix A Troubleshooting Q1. The PWR LED is not lit The PWR LED should be lit up when the power system works normally. If the PWR LED worked abnormally, please check as follows: 1. 2. Make sure that the power cable is connected properly, and the power contact is normal. Make sure the voltage of the power supply meets the requirement of the input voltage of the switch. Q2. The Speed or PoE LED is not lit when a device is connected to the corresponding port Please check as follows: 1.
Smart PoE+ Switch Appendix B Specifications Item Standards Content IEEE802.3i, IEEE802.3u, IEEE802.3ab, IEEE802.3z, IEEE802.3ad, IEEE802.3af, IEEE802.3at, IEEE802.3x, IEEE802.1p, IEEE802.1q, IEEE802.1x, IEEE802.1d, IEEE802.1s, IEEE802.1w 10Base-T 100Base-TX 100Base-FX 100Base-LX10 Transmission Medium 100Base-BX10 1000Base-T 1000Base-SX 1000Base-LX UTP/STP of Cat. 3 or above(maximum 100m) 2-pair UTP/STP of Cat.
For technical support and other information, please visit http://www.tp-link.com/support, or simply scan the QR code. The products of TP-Link partly contain software code developed by third parties, including software code subject to the GNU General Public License (“GPL”). As applicable, the terms of the GPL and any information on obtaining access to the respective GPL Code used in TP-Link products are available to you in GPL-Code-Centre under (http://www.tp-link.com/en/support/gpl/).