CLI Reference Guide

no lldp hold-multiplier
Parameter
multiplier —— Configure the Hold Multiplier parameter. It ranges from 2 to 10. By
default, it is 4.
Command Mode
Global Configuration Mode
Example
Specify Hold Multiplier as 5:
TL-SG3424P(config)# lldp hold-multiplier 5
lldp timer
Description
The lldp timer command is used to configure the parameters about transmission.
To return to the default configuration, please use no lldp timer command.
Syntax
lldp timer { tx-in terv al tx-interval | tx-de lay tx-delay | re init-de lay reinit-delay |
notify-interval notify-interval | fast-count fast-count }
no lldp timer { tx-interval | tx-delay | reinit-delay | notify-interval | fast-count }
Parameter
tx-interval —— Configure the interval for the local device to transmit LLDPDU to
its neighbors. The value ranges from 5 to 32768 seconds and the default value is
30 seconds.
tx-delay —— Configure a value from 1 to 8192 in seconds to specify the time for
the local device to transmit LLDPDU to its neighbors after changes occur so as
to prevent LLDPDU being sent frequently. By default, it is 2 seconds.
reinit-delay —— This parameter indicates the amount of delay from when LLDP
status becomes "disable" until re-initialization will be attempted. The value
ranges from 1 to 10 seconds and the default value is 3 seconds.
notify-interval —— Specify the interval of Trap message which will be sent from
local device to network management system. The value ranges from 5 to 3600
seconds and the default value is 5 seconds.
fast-count —— When the port's LLDP state transforms from Disable (or Rx_Only)
to Tx&Rx (or Tx_Only), the fast start mechanism will be enabled, that is, the
257