HOW TO DESIGNATE A MODEL:
Series Number
Unit Wattage
050=500 075=750 100=1000
125=1250 150=1500 200=2000
Unit Length
1=18” 2=28” 3=36”
4=48” 5=60” 6=72”
H 880 3 100
Element Voltage
E=120 F=208 G=277 H=240
L=346 P=480 U=600
5.00”
18.00”
ACCESS DOOR
4.00” Minimum
FLOOR
NOTE:
Allow 12 inch
clearance on left
end of unit and 4”
to the floor.
left side view
WARNING: This product can expose you
to chemicals including nickel which is known
to the State of California to cause cancer,
and chromium, which is known to the State
of California to cause birth defects and/or
reproductive harm. For more information go
to www.P65Warnings.ca.gov.
!
8800 Series Institutional Wall Convector
Optional In-Built Controls
CABINET:
Institutional enclosure 11 gauge perforated steel with sloped top design. Heavy duty end caps welded to the enclosure. Control
compartment for housing thermostat and disconnect switch is accessible by use of security type fastener. The entire enclosure is
protected by epoxy powder coated paint nish.
ELEMENT:
All steel high mass element construction with Nickel-Chromium resistance wire embedded in compacted efcient dielectric to
ensure proper heat transfer. Aluminum ns mechanically bonded to steel tube allows for increased surface area and even heat
transfer.
LIMIT CONTROLS:
Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating
temperatures are exceeded.
WIRING:
Wiring connections shall be made in left end of cabinet enclosure. Wiring must enter into control enclosure behind perforated
steel grill.
CONTROLS:
All controls are accessible only through control enclosure door. Security type fasteners restrict access to controls. Built in
thermostat and disconnect switch with manual adjustment are located in control enclosure.
Product Specications
• Single phase heaters available in all common voltages from 120V
to 600V.
• 11 gauge perforated steel housing powder coated with textured
ivory nish.
• Tamper proof left side control panel houses built-in single pole
thermostat - range 40°F-110°F and disconnect switch. Thermostat
on120V-277V units is line voltage and low voltage (24V) on
346V-600V units.
• Linear limit type thermal overload with automatic reset.
• Tamper proof fasteners
• Stainless steel element with Aluminum ns.
• Made in U.S.A.
Note: Not for residential applications.
*Not available on international models
SUFFIX DESCRIPTION
LIST
T2 Tamperproof, Hydraulic, Double pole In-Built thermostat range 40°-110°F, 25 Amp
165
24V* 24 Volt In-Built single pole thermostat for 120V 208V, 240V & 277V models. 40°-110°F