User guide
TP-1700P
12-Volt, ‘‘Instant On,’’ High-Intensity UV 
Leak Detection Lamp
U.S. Patents 5,788,364 and 5,905,268
SAVE THESE INSTRUCTIONS
WARNING
• RISK OF EXPLOSION: This equipment has internal arcing
or sparking parts that should not be exposed to flammable
vapors. It should be located in an area providing at least
four air changes per hour, or should be located at least 
18 inches above the floor.
• Do not touch the glass UV filter while in use.
• Use for a maximum of 5 minutes and allow a 10-minute 
cooling period before restarting. A series of short 
inspection intervals are recommended.
• Do not secure the momentary ON/OFF switch in the ON 
position. This will void the lamp’s warranty.
• Always disconnect the lamp from the power source 
and allow it to cool to the touch before storing or 
disassembling.
OPERATION
1. Turn off the engine.
2. Add fluorescent dye to the system. For best results, use 
OEM-approved Tracerline
®
Fluoro-Lite
®
and Dye-Lite
®
dyes.
3. Run the engine and/or system for 5 to 10 minutes to circulate 
the dye. Turn off the engine.
4. Connect the battery clips to any 12-volt vehicle battery or 
regulated 12 VDC, 5 amp power source.
5. Do not look directly into the UV light.You must wear the 
TP-9939 UV-absorbing clear glasses supplied with the 
lamp to protect your eyes.
6. Scan the system with the lamp. Leaks will show with a bright
fluorescent glow. The leaks will show best under low light 
conditions.
7. After the leaks are repaired, clean off the dye residue with 
GLO-AWAY™ dye cleaner and reinspect with the lamp.
TO REPLACE THE FILTER LENS 
Use only the TP-1712 filter lens.
1. Twist off the filter lens holder (1) and remove the retaining 
ring (3) to release the filter lens (2).
2. Using a clean cloth, press the new filter lens into the holder
and replace the retaining ring.
3. Make sure the IR deflector (4) is resting on the reflector (7)
above the bulb.
4. Align the filter lens holder into the notches on the lamp and
twist the holder back into place.
TO REPLACE THE BULB 
Use only the 50-watt TP-1510 bulb. Using any other bulb
may damage the lamp and will void the warranty.
1. Remove the filter assembly. Pull the bulb (5) from inside 
the reflector.
2. Using a clean cloth, press the new bulb through the bulb 
support (6) and reflector into thebi-pin socket (8) firmly 
but gently.
3. Replace the IR deflector and reattach the filter/lens assembly.
NOTE: A discolored UV bulb indicates that replacement is 
necessary. The average rated life of the bulb is 50 hours.
IMPORTANT SAFETY INSTRUCTIONS
1. Read all instructions.
2. Care must be taken as burns can occur from touching hot 
parts.
3. Do not operate the lamp with a damaged cord or if the lamp
has been damaged.
4. Do not let the cord hang over edge of table, bench or counter,
or come in contact with hot manifolds or moving fan blades.
5. To protect against risk of fire, do not operate the lamp in the 
vicinity of open containers of fuel (gasoline).
6. Adequate ventilation should be provided when working on 
operating combustion engines.
Do not use below garage floor or grade level.
Ne pas utiliser en fosse ou en dessous du niveau du sol.
WARRANTY
The warranty policy for the lamp is provided on the Certificate 
of Limited Warranty enclosed separately with each unit.
NOTE: For assistance of any kind, contact the Customer Service
Department at Tracer Products. In the U.S. and Canada, call 
toll free at 1-800-641-1133. Outside the United States, call 
516-333-1254.
NO. PART NO. DESCRIPTION
1  120838 FILTER LENS HOLDER
2  TP-1712 FILTER LENS, UV, 3 IN (7.6 CM) 
3  122381 RETAINING RING
4  103783 DEFLECTOR, INFRARED (IR)
5 TP-1510 BULB, 50W
6 105199 BULB SUPPORT RING
7 120840 REFLECTOR
8  100090 SOCKET, BI-PIN
9  100068 SWITCH, ROCKER
10 121596  CORD, 12 FT (3.7 M), 
COILED WITH ALLIGATOR CLIPS
TP-1700P
Lampe 12 volts à « Allumage immédiat »,
de détection de fuites à lumière UV de haute intensité
Brevets US 5,788,364 et 5,905,268
CONSERVER CES INSTRUCTIONS
AVERTISSEMENT
• RISQUE D’EXPLOSION. Cet équipement contient des
pièces pouvant émettre un arc électrique ou des étincelles
qui ne doivent pas entrer en contact avec des vapeurs
inflammables. Il doit être utilisé dans un espace dans
lequel l'air est au moins renouvelé quatre fois par heure 
ou doit être surélevé de 46 cm au moins au-dessus du sol.
• Ne pas toucher le filtre en verre à rayons ultraviolets 
pendant l’utilisation.
• Utiliser la lampe pendant 5 minutes au maximum et 
laissez-la refroidir pendant 10 minutes avant de la 
réutiliser. Des inspections, brèves et intermittentes
réduiront l’accumulation de chaleur et augmenteront la
durée d’utilisation de l’ampoule.
• L'interrupteur temporaire MARCHE/ARRÊT (ON/OFF) ne
doit pas être verrouillé en position MARCHE (ON). Ceci
annulera la garantie de la lampe.
• Toujours débrancher la lampe de sa source d'alimentation 
électrique et la laisser se refroidir jusqu'à pouvoir la
toucher avant de la ranger ou de la démonter.
RACERLINE
 ®
RACERLINE
 ®
English
French