U.S. Patent 6,573,665
DANGER
Ultraviolet radiation emitted from this product. Avoid exposure. ALWAYS WEAR
PROTECTIVE CLOTHING. EXPOSURE MAY CAUSE PREMATURE AGING OF THE
SKIN AND CANCER. ALWAYS WEAR PROTECTIVE EYEWEAR; FAILURE TO DO
SO MAY RESULT IN SEVERE BURNS OR LONG TERM INJURY TO EYE. Never
look directly into the lamp. Exposure can cause eye and skin allergy and allergic
reactions. Medications or cosmetics may increase your sensitivity to ultraviolet
radiation. Consult physician before operating this product if you are using
medications or have a history of skin problems or believe yourself especially
sensitive to sunlight.
FOR PROFESSIONAL EXAMINATION USE ONLY
IMPORTANT SAFETY INSTRUCTIONS
1. Read all instructions.
2. Care must be taken, as burns can occur from touching hot parts.
3. Do not operate the lamp with a damaged cord or if the lamp has been damaged.
4. You must wear the TP-9940 fluorescence-enhancing, protective glasses supplied to
protect your eyes and to make leaks clearly visible.
5. Don’t touch the hot filter of the lamp. Never operate the lamp with the UV filter lens
removed.
6. Never use this equipment in any manner not specified in these instructions
because the protection provided by the equipment may be impaired.
SAVE THESE INSTRUCTIONS
OPERATION
1. Turn off the engine before performing any leak detection inspections.
2. Add fluorescent dye to the system. For best results, use OEM-approved Tracerline
Fluoro-Lite® and Dye-Lite® dyes. See the dye instructions for full information.
3. Run the engine and/or system for 5 to 10 minutes to circulate the dye. Turn off the
engine.
4. Connect the plug to a power source that complies with the electrical requirements
specified on the lamp’s label.
5. Push the switch on the ballast. The lamp will achieve maximum output within
seconds.
6. While wearing the TP-9940 glasses, scan the system with the lamp. The leaks will show
best under low light conditions.
7. When the lamp is used intermittently at frequent intervals, leave the lamp burning
continuously rather than turning it on and off repeatedly. This extends bulb life. If the
lamp is turned off, it can be restarted immediately.
8. After the leaks are repaired, clean off the dye residue with GLO-AWAY™ dye
cleaner and reinspect with the lamp.
FOR AC OPERATION
1. Align the top notch of the 6-pin plug on the AC cord to the notch in the ballast
outlet; turn the locking ring to the right over the plug to secure.
2. Connect the ballast plug to a power source that complies with the electrical
requirements specified on the lamp’s label.
3. Push the rocker switch on the ballast.
Vorsicht (siehe Begleitunterlagen)
POSTEN TEILE BESCHREIBUNG
3 106081 FILTERHALTER, SILIKON
5
TP-1050 FILTERLINSE
TP-1050D FILTERLINSE (DIFFUNDIEREND)
7
TP-35100 BIRNEN- /REFLEKTOR-SET, 35 W SPOTLICHT
TP-35100F BIRNEN- /REFLEKTOR-SET, 35 W FLUTLICHT
9 118821 STARTER/FASSUNG
11 PC-0270 LAMPENGEHÄUSE
13 TP-1601A PISTOLENGRIFF
15 EH-0124 ZUGENTLASTUNG (NICHT ABGEBILDET)
17 119799 KABEL, SEKUNDÄR, 2,4 M
19 118820
VORSCHALTGERÄT, HID, 35 W, AC,
ELEKTRONISCH
21 118822 WECHSELRICHTER, 100 W, 12 V DC ZU 120 V AC
23 100253 WIPPENSCHALTER AM VORSCHALTGERÄT
25 107923 ABNEHMBARER AC KABELSATZ, 2,4 M, 120 V, 100 V
27 107924 ABNEHMBARER AC KABELSATZ, 2,4 M, 230 V
29 107925 ABNEHMBARER DC KABELSATZ, 0,9 M, 12 V
31 119954 GRIFF, VORSCHALTGERÄT
33 MC-0158 BEFESTIGUNGSSTIFT
35 122122 WIPPENSCHALTER AM WECHSELRICHTER
15