Schematics

SAR REFERENCE DIPOLE CALIBRATION REPORT
Ref: ACR.262.5.20.MVGB.A
1 INTRODUCTION
This document contains a summary of the requirements set forth by the IEEE 1528, OET 65 Bulletin
C and CEI/IEC 62209 standards for reference dipoles used for SAR measurement system validations
and the measurements that were performed to verify that the product complies with the fore
mentioned standards.
2 DEVICE UNDER TEST
Device Under Test
Device Type COMOSAR 835 MHz REFERENCE DIPOLE
Manufacturer MVG
Model SID835
Serial Number SN 30/14 DIP0G835-332
Product Condition (new / used) Used
A yearly calibration interval is recommended.
3 PRODUCT DESCRIPTION
3.1 GENERAL INFORMATION
MVG’s COMOSAR Validation Dipoles are built in accordance to the IEEE 1528, OET 65 Bulletin
C and CEI/IEC 62209 standards. The product is designed for use with the COMOSAR test bench
only.
Figure 1 MVG COMOSAR Validation Dipole
Page: 4/11
This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used
only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG.