Datasheet
Safety Standards
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Medical Equipment
EN 60601-1
IEC 60601-1
ANSI/AAMI ES 60601-1
2 x MOPP (Means Of Patient Protection)
- Certification Documents
www.tracopower.com/overview/thm15wi
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMI Emissions
EN 60601-1-2 edition 4 (Medical Devices)
- Conducted Emissions
EN 55011 class A (internal filter)
EN 55011 class B (with external filter)
EN 55032 class A (internal filter)
EN 55032 class B (with external filter)
FCC Part 18, class A
FCC Part 18, class B
- Radiated Emissions
EN 55011 class A (internal filter)
EN 55011 class B (with external filter)
EN 55032 class A (internal filter)
EN 55032 class B (with external filter)
FCC Part 18, class A
FCC Part 18, class B
External filter proposal:
www.tracopower.com/overview/thm15wi
EMS Immunity
EN 60601-1-2 edition 4 (Medical Devices)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±15 kV, perf. criteria A
Contact:
EN 61000-4-2, ±8 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
Ext. input component:
24 Vin models: 2 x KY 220 µF // TVS SMDJ58A
48 Vin models: 2 x KY 220 µF // TVS SMDJ120A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +85°C
- Case Temperature
+105°C max.
- Storage Temperature
–55°C to +125°C
Power Derating
- High Temperature
2.5 %/K above 65°C
Over Temperature
Protection Switch Off
- Protection Mode
115°C typ. (Automatic recovery)
- Measurement Point
Case
Cooling System
Natural convection (20 LFM)
Remote Control
- Voltage Controlled Remote
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
- Off Idle Input Current
2.5 mA typ.
- Remote Pin Input Current
-0.5 to 1.0 mA
(Only for optional models with remote-control. In-
verse models available.)
Altitude During Operation
5'000 m max.
General Specifications
THM 15WI Series, 15 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
September 16, 2019