Datasheet

Application Note
Created by Traco Electronic AG Arp. www.tracopower.com Date: May 31
th
, 2013 / Rev.: 1.2
/
Page 42 / 52
20W Single & Dual Output
Testing Configurations
Input reflected-ripple current measurement test up
L
+
C2
+
C1
CURRENT PROBE MEASURE POINT
BATTERY
+Vin
-Vin
Component Value Voltage Reference
L 1
2
μH ---- ----
C1 10μ
F
100V
A
luminum Electrolytic Capacitor
C
2
10μ
F
100V
A
luminum Electrolytic Capacitor
Peak-to-peak output ripple & noise measurement test up
Output voltage and efficiency measurement test up
Note: All measurements are taken at the module terminals.
%100
inin
oo
IV
IV
Efficiency