Datasheet

Application Note
Created by Traco Electronic AG Arp. www.tracopower.com Date: May 31
th
, 2013 / Rev.: 1.2
/
Page 5 / 52
20W Single & Dual Output
Environmental Specifications
Thermal shock MIL-STD-810F
Vibration MIL-STD-810F
Relative humidity 5% to 95% RH
EMC Characteristics
EMI (See Page 43 - 45) EN55022 Class B
ESD EN61000-4-2
Air
Contact
±8KV
±6KV
Performance Criteria A
Radiated immunity EN61000-4-3 10 V/m Performance Criteria A
Fast transient (Burst)* EN61000-4-4 ±2KV Performance Criteria A
Surge* EN61000-4-5 ±2KV Performance Criteria A
Conducted immunity EN61000-4-6 10 V
r.m.s
Performance Criteria A
* An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
We suggest to use following filter capacitor: Nippon Chemi-Con KY-series, 220μF/100V, ESR 48m.