Data Sheet

Safety Standards
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/tel10
Safety Specifications
EMI Emissions
- Conducted Emissions
EN 55032 class A (internal filter)
EN 55032 class B (with external filter)
- Radiated Emissions
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
External filter proposal:
www.tracopower.com/overview/tel10
EMS Immunity
EN 55024 (IT Equipment)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 20 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
External filter proposal:
www.tracopower.com/overview/tel10
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +85°C
- Case Temperature
+105°C max.
- Storage Temperature
–50°C to +125°C
Power Derating
- High Temperature
See application note:
www.tracopower.com/overview/tel10
Cooling System
Natural convection (20 LFM)
Switching Frequency
357 - 483 kHz (PWM)
420 kHz typ. (PWM)
Insulation System
Functional Insulation
Isolation Test Voltage
- Input to Output, 60 s
1'060 VAC
- Input to Output, 1 s
1'800 VDC
- Input to Case, 60 s
707 VAC
- Output to Case, 60 s
707 VAC
Isolation Resistance
- Input to Output, 500 VDC
1'000 MOhm min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
1'500 pF max.
Reliability
- Calculated MTBF
1'800'000 h (MIL-HDBK-217F, ground benign)
Housing Material
Alu alloy, black anodized coating
Potting Material
Epoxy (UL 94 V-0 rated)
Pin Material
Tinned Copper
Soldering Profile
Wave Soldering (1.5mm from casing)
260°C / 10 s max.
Connection Type
THD (Through-Hole Device)
Weight
6.5 g
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
General Specifications
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tel10
TEL 10 Series, 10 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
September 18, 2019
Page 3 / 4