Features
◆
Wide 2:1 input range
◆ High power density
◆ Operating temperature range
–40°C to +85°C
◆ Indefinite short circuit protection
◆ I/O isolation 1500 VDC
◆ Input filter to meet EN 55022, Class A
and FCC, level A without external
components
◆ Industry standard pinout
◆ Shielded metal case with insulated
baseplate
◆ High reliability, MTBF >1 Mio. h
◆ 3-year product warranty
DC/DC Converters
TEN 10 Series, 10 Watt
The TEN 10 series is a family of high performance 10W DC/DC converters in a
compact 2” x 1” low profile package with industry standard footprint. A high effici-
ency allows a wide operating temperature range of –40°C to +85°C. A built-in EMI
filter is built in to meet EN 55022, class A without any external components.
Further standard features include over voltage protection and short-circuit protec-
tion. Typical applications for these converters are battery operated equipment, in-
strumentation, distributed power architectures in communication and industrial elec-
tronics, everywhere where isolated, tightly regulated voltages are required.
Order code Input voltage range Output voltage Output current max. Efficiency typ.
TEN 10-1210
3.3 VDC 2’400 mA 72 %
TEN 10-1211
5 VDC 2‘000 mA 77 %
TEN 10-1212
12 VDC 830 mA 80 %
TEN 10-1213 9 – 18 VDC
15 VDC 670 mA 80 %
TEN 10-1215
(12 VDC nominal)
24 VDC 415 mA 81 %
TEN 10-1221
±5 VDC ±1‘000 mA 78 %
TEN 10-1222
±12 VDC ±415 mA 81 %
TEN 10-1223
±15 VDC ±330 mA 80 %
TEN 10-2410
3.3 VDC 2’400 mA 76 %
TEN 10-2411
5 VDC 2‘000 mA 78 %
TEN 10-2412
12 VDC 830 mA 82 %
TEN 10-2413 18 – 36 VDC
15 VDC 670 mA 82 %
TEN 10-2415
(24 VDC nominal)
24 VDC 415 mA 83 %
TEN 10-2421
±5 VDC ±1‘000 mA 80 %
TEN 10-2422
±12 VDC ±415 mA 82 %
TEN 10-2423
±15 VDC ±330 mA 82 %
TEN 10-4810
3.3 VDC 2‘400 mA 76 %
TEN 10-4811
5 VDC 2‘000 mA 80 %
TEN 10-4812
12 VDC 830 mA 82 %
TEN 10-4813 36 – 75 VDC
15 VDC 670 mA 83 %
TEN 10-4815
(48 VDC nomial)
24 VDC 415 mA 83 %
TEN 10-4821
±5 VDC ±1‘000 mA 81 %
TEN 10-4822
±12 VDC ±415 mA 83 %
TEN 10-4823
±15 VDC ±330 mA 83 %
Models
UL 60950-1
not recommended for new design in