Datasheet

http://w ww.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
General Specifications
EMC immunity – Electrostatic discharge ESD EN 61000-4-2 8 kV / 6 kV, criteria B
– RF field susceptibility EN 61000-4-3 10 V/m, criteria A
– Electrical fast transient / burst immunity input EN 61000-4-4 ±2 kV, criteria B
– Surge immunity EN 61000-4-5 ±1 kV, criteria B
– Immunity to conducted RF disturbances EN 61000-4-6 10 Vrms, criteria A
Thermal shock, mechanical shock & vibration EN 61373, MIL-STD-810F
Test conditions www.tracopower.com/products/mil810.pdf
Safety standards UL 60950-1, IEC/EN 60950-1
Safety approvals – UL/cUL www.ul.com -> certifications -> File e188913
Environmental compliance – Reach www.tracopower.com/overview/ten10
– RoHS directive 2011/65/EU
Physical Specifications
Casing material Steel chrome-nickel plated
Baseplate material Epoxy
Potting material Silicon rubber TES (UL 94V-0 rated)
Weight 30 g (1.2 oz)
Soldering temperature max. 265°C / 10 sec.
Outline Dimensions
DC/DC Converters
TEN 10 Series 10 Watt
Outline Dimensions
Pin Single Dual
1
+Vin (Vcc) +Vin (Vcc)
2
–Vin (GND) –Vin (GND)
3
+Vout +Vout
4
No pin Common
5
–Vout –Vout
Pin-Out
Dimensions in [mm], () = Inch
Pin diameter: 1.0 ±0.05 (0.039 ±0.0019)
Pin pitch tolerances: ±0.25 (±0.01)
Casing tolerances: ±0.5 (±0.02)
5.08
10.16
25.4
10.2
5.6
50.8
15.2
20.32
Insulated baseplate
(2.0)
(0.8)
(0.6)
(0.2)
(0.4)
(0.4)
(1.0)
2.5
(0.1)
(0.4)
(0.22)
Bottom View
1
4
3
2
5
10.16
10.2
(0.4)