Datasheet
http://www.tracopower.com Page 3 of 4
General Specifications
Capacitive load 1.5 / 2.5 / 3.3 Vout models: 20’000 µF
5.1 Vout models: 14’400 µF
12 Vout models: 3’000 µF
15 Vout models: 2’000 µF
±5 Vout models: ±3’000 µF
±12 Vout models: ±2’000 µF
±15 Vout models: ±1’300 µF
Temperature ranges – Operating – 40°C to +85°C
– Case temperature +100°C max.
– Storage – 55°C to +125°C
Load derating 3.3 %/K above 60°C
Humidity (non condensing) 5 % to 95 % rel H max.
Thermal inpedance – Natural convection 12 °C/W
– Natural convection with heat sink 10 °C/W
Reliability, calculated MTBF (MIL-HDBK-217F, @ 25°C, ground benign) 550’000 h
Isolation voltage (60 sec.) – Input/Output 1‘500 VDC
Isolation capacity – Input/Output 1500 pF max.
Isolation resistance – Input/Output (500 VDC) >1’000 MOhm
Remote On/Off: – On: 3 to 12 VDC or open circuit.
– Off: 0 to 1.2 VDC or short circuit pin 3 and pin 2
– Standby current: 3 mA max.
Switching frequency (fixed) 430 kHz typ. (puls width modulation)
Vibration and thermal shock MIL-STD-810E
Safety standards UL/cUL 60950-1, IEC/EN 60950-1 compliance
Safety approvals UL (File no.: tba)
DC/DC Converters
TEN 30 Series, 30 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Output Voltage Adjustment
Rd
Trim
+Vout
Ru
Trim
-
Vout
Trim up Trim down
Physical Specifications
Casing material copper, nickel plated
Baseplate non conductive FR4
Potting material epoxy (UL 94V-0 -rated)
Weight 31 g (1.1 oz)
Soldering temperature max. 265°C / 10 sec.
Nominal output voltage at open Trim input!
Rd [kohm]
output 1.5 2.5 3.3V 5.1V 12V 15V
–5% 0.68 6.2 8.2 6.2 56 56
–10% 0.062 0.75 0.62 0.82 5.6 2.2
Ru [kohm]
output 1.5 2.5 3.3V 5.1V 12V 15V
+5% 0.56 4.3 6.8 5.1 43 47
+10% 0.051 0.33 0.75 0.75 4.3 1.8