Datasheet

Output Voltage Adjustment
±10% (single output models only)
(By external trim resistor)
See application note:
www.tracopower.com/overview/ten30
Output power must not exceed rated power!
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.2% max.
dual output models:
0.2% max.
- Load Variation (0 - 100%)
single output models:
0.5% max.
dual output models:
1% max. (Output 1)
1% max. (Output 2)
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
Ripple and Noise
(20 MHz Bandwidth)
- single output
1.5 Vout models:
100 mVp-p typ. (w/ 1 µF, 50 V MLCC)
2.5 Vout models:
100 mVp-p typ. (w/ 1 µF, 50 V MLCC)
3.3 Vout models:
100 mVp-p typ. (w/ 1 µF, 50 V MLCC)
5.1 Vout models:
100 mVp-p typ. (w/ 1 µF, 50 V MLCC)
12 Vout models:
150 mVp-p typ. (w/ 1 µF, 50 V MLCC)
15 Vout models:
150 mVp-p typ. (w/ 1 µF, 50 V MLCC)
- dual output
5 / -5 Vout models:
100 / 100 mVp-p typ. (w/ 1 µF, 50 V MLCC)
12 / -12 Vout models:
150 / 150 mVp-p typ. (w/ 1 µF, 50 V MLCC)
15 / -15 Vout models:
150 / 150 mVp-p typ. (w/ 1 µF, 50 V MLCC)
Capacitive Load
- single output
1.5 Vout models:
20'000 µF max.
2.5 Vout models:
20'000 µF max.
3.3 Vout models:
20'000 µF max.
5.1 Vout models:
14'400 µF max.
12 Vout models:
3'000 µF max.
15 Vout models:
2'000 µF max.
- dual output
5 / -5 Vout models:
3'000 / 3'000 µF max.
12 / -12 Vout models:
2'000 / 2'000 µF max.
15 / -15 Vout models:
1'300 / 1'300 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
30 ms typ.
Short Circuit Protection
Continuous, Automatic recovery
Overload Protection
Indefinite Mode
Output Current Limitation
150% typ. of Iout max.
Overvoltage Protection
125% typ. of Vout nom.
(depending on model)
2 VDC typ. (1.5 Vout models)
3.3 VDC typ. (2.5 Vout models)
3.9 VDC typ. (3.3 Vout models)
6.2 VDC typ. (±5 & 5.1 Vout models)
15 VDC typ. (±12 Vout models)
18 VDC typ. (±15 Vout models)
Transient Response
- Peak Variation
450 mV max. (25% Load Step)
- Response Time
250 µs typ. (25% Load Step)
Output Specifications
Safety Standards
- IT / Multimedia Equipment
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/ten30
Safety Specifications
TEN 30 Series, 30 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 3 / 5