Datasheet
Pollution Degree
PD 2
Over Voltage Category
OVC I
EMI Emissions
- Conducted Emissions
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
- Radiated Emissions
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
External filter proposal:
www.tracopower.com/overview/ten30
EMS Immunity
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
Ext. input component:
12 Vin & 24 Vin models (KY 330 µF / 50 V)
48 Vin models (KY 220 µF / 100V)
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +80°C
- Case Temperature
+105°C max.
- Storage Temperature
–55°C to +125°C
Power Derating
- High Temperature
Depending on model
See application note:
www.tracopower.com/overview/ten30
Over Temperature
Protection Switch Off
- Protection Mode
115°C typ. (Automatic recovery at 105°C typ.)
- Measurement Point
Case
Cooling System
Natural convection (20 LFM)
Remote Control
- Voltage Controlled Remote
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
- Off Idle Input Current
3 mA typ.
- Remote Pin Input Current
-0.5 to 0.5 mA
Altitude During Operation
5'000 m max.
Switching Frequency
387 - 473 kHz (PWM)
430 kHz typ. (PWM)
Insulation System
Functional Insulation
Isolation Test Voltage
- Input to Output, 60 s
1'600 VDC
- Input to Case, 60 s
1'600 VDC
- Output to Case, 60 s
1'600 VDC
Isolation Resistance
- Input to Output, 500 VDC
1'000 MΩ min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
1'500 pF max.
Reliability
- Calculated MTBF
1'450'000 h (MIL-HDBK-217F, ground benign)
Washing Process
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Environment
- Vibration
MIL-STD-810F
7.7 g, 3 axis, random waveform, 60 min
- Mechanical Shock
MIL-STD-810F
40 g, 3 axis, terminal peak sawtooth, 11 ms
- Thermal Shock
MIL-STD-810F
-55°C to +125°C, 72 cycles, 30 min each
Housing Material
Copper, Nickel plated
Base Material
Non-conductive FR4 (UL 94 V-0 rated)
Potting Material
Epoxy (UL 94 V-0 rated)
General Specifications
TEN 30 Series, 30 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023