Datasheet

Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.5% max.
dual output models:
0.5% max.
triple output models:
1% max.
5% max. (aux)
- Load Variation (0 - 100%)
single output models:
0.5% max.
dual output models:
1% max. (Output 1)
1% max. (Output 2)
triple output models:
2% max. (Output 1)
5% max. (Output 2)
5% max. (Output 3)
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
triple output models:
1% max.
5% max. (aux)
Ripple and Noise
(20 MHz Bandwidth)
- single output
3.3 Vout:
50 mVp-p typ. (w/ 0.1 μF MLCC)
5 Vout:
50 mVp-p typ. (w/ 0.1 μF MLCC)
12 Vout:
75 mVp-p typ. (w/ 0.1 μF MLCC)
- dual output
3.3 / 5 Vout:
100 / 100 mVp-p typ. (w/ 1 uF MLCC)
12 / -12 Vout:
120 / 120 mVp-p typ. (w/ 0.1 μF MLCC)
15 / -15 Vout:
150 / 150 mVp-p typ. (w/ 0.1 μF MLCC)
- triple output
3.3 / 12 / -12 Vout:
50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC)
3.3 / 15 / -15 Vout:
50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC)
5 / 12 / -12 Vout:
50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC)
5 / 15 / -15 Vout:
50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC)
Capacitive Load
- single output
3.3 Vout:
21'000 µF max.
5 Vout:
13'600 µF max.
12 Vout:
2'360 µF max.
- dual output
3.3 / 5 Vout:
11'000 / 6'800 µF max.
12 / -12 Vout:
1'200 / 1'200 µF max.
15 / -15 Vout:
750 / 750 µF max.
- triple output
3.3 / 12 / -12 Vout:
13'000 / 330 / 330 µF max.
3.3 / 15 / -15 Vout:
13'000 / 110 / 110 µF max.
5 / 12 / -12 Vout:
6'800 / 330 / 330 µF max.
5 / 15 / -15 Vout:
6'800 / 110 / 110 µF max.
Minimum Load
- single output
3.3 Vout:
0 % of Iout max.
5 Vout:
0 % of Iout max.
12 Vout:
0 % of Iout max.
- dual output
3.3 / 5 Vout:
0 % of Iout max.
12 / -12 Vout:
8 % of Iout max.
15 / -15 Vout:
8 % of Iout max.
- triple output
3.3 / 12 / -12 Vout:
10 % of Iout max.
3.3 / 15 / -15 Vout:
10 % of Iout max.
5 / 12 / -12 Vout:
10 % of Iout max.
5 / 15 / -15 Vout:
10 % of Iout max.
Temperature Coefficient
±0.02 %/K max.
Start-up Time
25 ms typ. (Power On)
25 ms typ. (Remote On)
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
150% max. of Iout max.
Overvoltage Protection
118 - 125% of Vout nom.
(depending on model)
3.9 VDC typ. (3.3 VDC outputs)
6.2 VDC typ. (5 VDC outputs)
15 VDC typ. (12 VDC outputs)
18 VDC typ. (15 VDC outputs)
(By Zener diode)
Transient Response
- Response Time
250 µs typ. (25% Load Step)
TEN 40 Series, 40 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 3 / 6