Datasheet
TEN 6WIN Series
Application Note
http://www.tracopower.com Page 2 of 43
Absolute Maximum Rating
Parameter Model Min Max Unit
Input Voltage
VDCInput Surge Voltage ( 1sec. ) TEN 6-24xxWIN --- 50
TEN 6-48xxWIN --- 100
Operating Ambient Temperature
All
℃
Without Derating -40 +70
With Derating -40 +85
Operating Case Temperature All --- +100
℃
Storage Temperature All -50 +125
℃
Output Specication
Parameter Model Min Nominal Max Unit
Output Voltage
(V
in
=V
in nom
; Full Load; T
A
=25℃)
TEN 6-xx10WIN 3.234 3.3 3.366
VDC
TEN 6-xx11WIN 4.9 5 5.1
TEN 6-xx12WIN 11.76 12 12.24
TEN 6-xx13WIN 14.7 15 15.3
TEN 6-xx15WIN 23.52 24 24.48
TEN 6-xx21WIN ±4.9 ±5 ±5.1
TEN 6-xx22WIN ±11.76 ±12 ±12.24
TEN 6-xx23WIN ±14.7 ±15 ±15.3
Output Regulation
Line (V
in min
to V
in max
at Full Load) ±0.1 ±0.5
%
Output Regulation
%
Load (0% to 100% of Full Load) ±0.6 ±1.2
Output Ripple & Noise
mV
P-P
Peak-to-Peak (20MHz bandwidth) All 50 80
Temperature Coefcient All --- ±0.01 ±0.02 %/℃
Output Voltage Overshoot
All --- --- 5 %
(V
in min
to V
in max
; Full Load; T
A
= 25℃)
Dynamic Load Response
All
(V
in
= V
in nom
; T
A
=25℃ Load step change form
form 75% to 100% or 100% to 75% of full Load)
Peak Deviation
±3
--- %
Recovery Time (V
out
< 10% peak deviation) 300 600 μS
Output Current
TEN 6-xx10WIN 0 --- 1200
mA
TEN 6-xx11WIN 0 --- 1200
TEN 6-xx12WIN 0 --- 500
TEN 6-xx13WIN 0 --- 400
TEN 6-xx15WIN 0 --- 250
TEN 6-xx21WIN 0 --- ±500
TEN 6-xx22WIN 0 --- ±250
TEN 6-xx23WIN 0 --- ±200
Output Over Current Protection All 110 150
---
%FL
Output Short Circuit Protection All Continuous