Datasheet

TEN 6WIN Series
Application Note
http://www.tracopower.com Page 39 of 43
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances
can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a
capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good
quality low Equivalent Series Resistance (ESR < 1.0 Ω at 100 KHz) capacitor of a 4.7µF for the 24V input devices
and a 2.2µF for the 48V devices.
Output Over Current Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry
and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from
voltage control to current control. The unit operates normally once the output current is brought back into its specied
range.
Short Circuitry Protection
Continuous, hiccup and auto-recovery mode. During short circuit, converter still shut down, The average current
during this condition will be very low and the device will be safe in this condition.