All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TEN 60WIN Series 60 Watt
General Specifications
Temperature ranges – Operating –40°C to +85°C (with derating)
– Casing temperature +105°C max.
– Storage –55°C to +125°C
Power derating – Natural convection 2.5 %/K above +50°C
– Natural convection with heat sink (optional) 2.25 %/K above +55°C
Thermal impedance – Natural convection 10.8 K/W
– Natural convection with heat sink (optional) 10.3 K/W
Over-temperatur protection at 115°C
Humidity (non condensing) 5 – 95 % rel. H
Isolation voltage (60 sec.) – Input / Output 1500 VDC
Isolation resistance – Input / Output >1 GOhm
Isolation capacitance – Input / Output 2’200 pF max.
Switching frequency 250 kHz typ. (pulse width modulation PWM)
Thermal shock, mechanical shock & vibration MIL-STD-810F
– Test conditions www.tracopower.com/products/mil810.pdf
Safety standards UL/cUL 60950-1, IEC/EN 60950-1
– Certification documents www.tracopower.com/overview/ten60win
Remote On/Off – On: 3.0 ... 12 VDC or open circuit
– Off: 0 ... 1.2 VDC or short circuit pin 3 and pin 2
– Off idle current: 3.0 mA
Reliability, calculated MTBF (MIL-HDBK-217F, at +70°C, ground benign) 850’000 h
Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Application note: www.tracopower.com/products/ten60win-application.pdf
Output Voltage Adjustment (for single output models only)
Rd
Trim
+Vout
Ru
Trim
-
Vout
Trim up Trim down
Nominal output voltage at open Trim input