Datasheet
Output Current Limitation
150% typ. of Iout max.
Transient Response
- Peak Variation
165 mV typ. / 264 mV max. (25% Load Step)
(3.3 Vout models)
250 mV typ. / 400 mV max. (25% Load Step)
(5 Vout models)
225 mV typ. / 450 mV max. (25% Load Step)
(other models)
- Response Time
200 µs typ. (25% Load Step)
Safety Standards
- IT / Multimedia Equipment
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/ten8
Pollution Degree
PD 2
Over Voltage Category
Not mains connected
Safety Specifications
EMI Emissions
- Conducted Emissions
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
- Radiated Emissions
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
External filter proposal:
www.tracopower.com/overview/ten8
EMS Immunity
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
Ext. input component:
Nippon chemi-con KY series, 220μF/100V
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +85°C
- Case Temperature
+100°C max.
- Storage Temperature
–55°C to +125°C
Power Derating
- High Temperature
Depending on model
See application note:
www.tracopower.com/overview/ten8
Cooling System
Natural convection (20 LFM)
Remote Control
- Voltage Controlled Remote
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
- Off Idle Input Current
2.5 mA max.
- Remote Pin Input Current
-0.5 to 0.5 mA
Altitude During Operation
4'000 m max.
Switching Frequency
270 - 330 kHz (PWM)
300 kHz typ. (PWM)
Insulation System
Functional Insulation
General Specifications
TEN 8 Series, 8 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 3 / 5