Datasheet
http://w ww.tracopower.com
Features
◆
Shielded metal case with screw terminals
◆ Ultra wide 4:1 input voltage ranges
8.5–36, 16.5–75, 43–160 VDC
◆ EN 50155 approval for railway applications
◆ Very high efficiency up to 87%
◆ Constant current output characteristic for
battery load applications
◆ Optional with input filter to meet
EN55022 class B
◆ Overtemperature protection
◆ Wide Operating temperature range:
–40°C to +75°C
◆ Reverse input protection
◆ Under voltage lock-out
◆ I/O isolation 2250 VDC
◆ Easy chassis and wall mounting
◆ 3-year product warranty
DC/DC Converters
TEP 150WI Series, 150 Watt
The modules have originally been designed for harsh industrial environment. High
EMC immunity against surge, burst, radiated and conducted disturbances and the
shock/ vibration and thermal shock resistance make them very popular for stringent
requirements. With the extended input voltage ranges that cover the nominal 24,
36, 72 and 110 VDC with ±40 % tolerance and the approval in accordance to
EN50155 standard they now also offer a reliable solution for mobile and stationary
railway applications. At 100% load the current characteristics goes from constant
voltage to constant current what makes the units also suitable for battery charger
applications. With protection against over-temperature, overload, short-circuit, re-
verse input, overvoltage and input under-voltage lock-out they are hard to destroy.
Page 1 of 5
Order code* Input voltage Output voltage Output current max. Efficiency typ.
TEP 150-2412WI
12 VDC 12.5 A 86 %
TEP 150-2413WI
9 – 36 VDC
15 VDC 10 A 86 %
TEP 150-2415WI
(24 VDC nominal)
24 VDC 6.3 A 87 %
TEP 150-2416WI
28 VDC 5.4 A 87 %
TEP 150-2418WI
48 VDC 3.2 A 86 %
TEP 150-4812WI
12 VDC 12.5 A 87 %
TEP 150-4813WI
18 – 75 VDC
15 VDC 10 A 87 %
TEP 150-4815WI
(48 VDC nominal)
24 VDC 6.3 A 88 %
TEP 150-4816WI
28 VDC 5.4 A 88 %
TEP 150-4818WI
48 VDC 3.2 A 87 %
TEP 150-7212WI
12 VDC 12.5 A 86 %
TEP 150-7213WI
43 – 160 VDC
15 VDC 10 A 86 %
TEP 150-7215WI
(110 VDC nominal)
24 VDC 6.3 A 87 %
TEP 150-7216WI
28 VDC 5.4 A 87 %
TEP 150-7218WI
48 VDC 3.2 A 86 %
Options
suffix –F
Modules with input filter to meet EN 55022 class B, see page 5
on demand Negative (passive = Off) remote On/Off function (standard is passive = On)range
Models
C B
Scheme
UL 60950-1