Datasheet

http://www.tracopower.com
DC/DC Converters
TEP 150WI Series 150 Watt
General Specifications
Temperature ranges – Operating –40°C to +75°C
– Case temperature +100°C max.
– Storage –55°C to +125°C
Thermal consideration – Mounting surface Optimize thermal coupling to heat conducting
surface. Not to mount on flammable surface!
– Derating and temperature test point see application note
Over temperature protection at 110°C (auto restart)
Vibration and thermal shock acc. MIL-STD-810F
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +40°C, ground benign) >135‘000 h
Isolation voltage (60 sec.) – Input/Output 2250 VDC (functional insulation)
– Input/Case 1500 VDC
– Output/Case 1500 VDC
Isolation capacitance – Input/Output 3500 pF max.
Isolation resistance – Input/Output (500 VDC) >1 GOhm min.
Switching frequency 220 – 330 kHz depending on model
(puls width modulation)
Safety standards UL 60950-1, IEC/EN 60950-1
Safety approvals – UL/cUL 60950-1 www.ul.com -> certifications -> File e188913
– CB test certificate (IEC 60950-1)
www.tracopower.com/products/tep150wi-cb.pdf
Remote On/Off – positive logic (standard) – On: 3 to 12 VDC or open circuit
– Off: 0 to 1.2 VDC
or short circuit pin 5 and 3
– negative logic (option -N) – On: 0 to 1.2 VDC
or short circuit pin 5 and 3
– Off: 3 to 12 VDC or open circuit
– Off idle current: 3 mA
Environmental compliance – Reach www.tracopower.com/products/tep150wi-reach.pdf
– RoHS RoHS directive 2002/95/EC
Physical Specifications
Casing material metal
Potting material silicon (UL 94V-0 rated)
Case protection IP 50 (in accordance to IEC/EN60529)
Weight 300 g (10.6 oz)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Page 3 of 5
Application note: www.tracopower.com/products/tep150wi-application.pdf