Datasheet

http://w ww.tracopower.com Page 1 of 4
DC/DC Converters
TEP 160 Series, 150 – 196 Watt
Features
◆
Compact metal package
◆ Wide 2:1 input voltage ranges
16.5–36, 33–75 VDC
◆ Very high efficiency up to 93%
◆ No minimum load
◆ Soft start
◆ Ajustable output voltage +10/-20%
◆ Sense line
◆ Remote On/Off input
◆ Reverse input voltage protection
◆ Over temperature protection
◆ Optional Heatsink
◆ 3-year product warranty
The TEP 160 Series is a family of isolated high performance dc-dc converter modules
with wide 2:1 input voltage ranges which come in a rugged, sealed industry stan-
dard half brick package.
A very high efficiency allows full power operation without forced air cooling at 25°C
This temperature can be increased to 40°C with optional mounted heatsink or up
to 60°C when mounted on an iron base plate. The very wide input voltage range
and reverse input voltage protection make these converters interesting solution for
battery operated systems. Typical applications are in telecom/datacom, industry
control and railway systems for on board power distribution.
These series is available in many optional designs on demand --> see options.
Order code Input voltage Output voltage Output current max. Efficiency typ.
TEP 160-2412
12 VDC 13 A 92 %
TEP 160-2413
16.5 – 36 VDC
15 VDC 10 A 92 %
TEP 160-2415
(24 VDC nominal)
24 VDC 6.5 A 93 %
TEP 160-2416
28 VDC 5.5 A 93 %
TEP 160-2418
48 VDC 3.3 A 92 %
TEP 160-4812
12 VDC 16 A 92 %
TEP 160-4813
15 VDC 13 A 93 %
TEP 160-4815 33 – 75 VDC
24 VDC 8 A 92 %
TEP 160-4816
(48 VDC nominal)
28 VDC 7 A 92 %
TEP 160-4818
48 VDC 4 A 92 %
TEP 160-48153
53 VDC 3.7 A 92 %
Standard Models
(Models pictured with optional heatsink)
TEP-HS1
Heat-sink for standard version (incl. mounting screws and thermal pad)
TCK-xxx
Common mode chokes for filter proposals to meet EN55022 class A/B --> see application note
on demand
Models with 3.3 VDC/~ 40 A or 5.0 VDC/~ 30 A output
Negative (passive = Off) Remote On/Off function (standard is passive = On)
Sync pin to synchronize switching frequency of up to 3 units (EMC reason)
Options