Datasheet

TEP 75WI Series
Application Note
http://www.tracopower.com Page 54 of 69
EMI considerations (continued)
These common mode choke have been dene as follow
TCK-064 Inductance1186μH±35%
Impedance21.56mΩ, max.
Rated current5.8A, max.
TCK-067 Inductance620μH±35%
Impedance25mΩ, max.
Rated current7.5A, max.
TCK-072 Inductance156μH±35%
Impedance15mΩ, max
Rated current11.3A, max.
TCK-073 Inductance305μH±35%
Impedance20mΩ, max.
Rated current11.3A, max.
Measurement Instrument (Test condition)
LHP 4263B LCR Meter (100KHz / 100mV)
DCRHIOKI 3540 mΩ HITESTER
IDCAgilent 34401A Meter
Recommended through holeΦ1.0mm
All dimensions in millimeters
The inductor has been dened as follow
TCK-099 Inductance4.7μH±20%
Impedance23.3mΩ, typ.
Rated current5A, max.
Measurement Instrument (Test condition)
LHP 4263B LCR Meter (100KHz / 250mV)
DCRHIOKI 3540 mΩ HITESTER
IDCAgilent 34401A Meter