Datasheet

TEP 75WI Series
Application Note
http://www.tracopower.com Page 6 of 69
Environmental Specication
Parameter Model Min Typ Max Unit
Operating ambient temperature (with derating) * All -40 85
Operating case temperature All -40 105
Storage temperature All -55 125
Over temperature protection (see page 58) All 115
Thermal impedance without Heat-sink
With 0.24” Height Heat-sink
With 0.45” Height Heat-sink
All
6.7
5.4
4.7
K/ Watt
K/ Watt
K/ Watt
Relative humidity All 5 95 % RH
Thermal shock MIL-STD-810F
Vibration MIL-STD-810F
* Test condition with vertical direction by natural convection (20FLM)
EMC characteristic
Environmental Phenomena Basic Standard Severity Performance Criteria
EMI Standard (see page 50)
Option TF
EN55011EN55022
EN55011EN55022
Class A
Class A
ESD EN61000-4-2
Air
Contact
±8KV
±6KV
A
Radiated immunity EN61000-4-3 20V/m A
Fast transient EN61000-4-4 ±2KV A
Surge EN61000-4-5
EN55024
EN50155
±1KV
±2KV
A
A
Conducted immunity EN61000-4-6 10Vr.m.s A
** The TEP 75WI series meets EMC characteristics only with external components connected before the input pin to the converter.
If customer only need to meet EN61000-4-4, EN61000-4-5, an external input lter capacitor is required. Recommended 1 pcs of aluminum
electrolytic capacitor (Nippon Chemi-con KY series, 220μF/100V, ESR 48mΩ) to connect in parallel. Recommended 2 pcs of aluminum
electrolytic capacitor (Nippon Chemi-con KXJ series, 150μF/200V) to connect in parallel.