Datasheet

TEP 75WI Series
Application Note
http://www.tracopower.com Page 52 of 69
EMI considerations (continued)
Suggested schematic for EN55022 conducted emission Class B limits
Recommended Layout With Input Filter
To meet conducted emissions EN55022 CLASS B needed the following components
TEP 75-24xxWI
Component Value Voltage Reference
C1C5 100 μF 50 V Nippon chemi-con KY series
C2C3C4C6C7 4.7 μF 50 V 1812 MLCC
C8C9C14C15 1000 pF 3 KV 1808 MLCC
C10C11C12C13 10 nF 2 KV 1812 MLCC
L1L2 305μH ± 35% ---- Common Choke, P/NTCK-073
TEP 75-48xxWI
Component Value Voltage Reference
C1C5 100 μF 100 V Nippon chemi-con KY series
C2C3C4C6C7 2.2 μF 100 V 1812 MLCC
C8C14C15 1000 pF 3 KV 1808 MLCC
C9 4700 pF 3 KV 1812 MLCC
C10C11C12C13 10 nF 2 KV 1812 MLCC
L1 1186 μH ± 35% ---- Common Choke, P/N: TCK-064
L2 156 μH ± 35% ---- Common Choke, P/N:PMT-072
Note1. Common mode choke have been dene and show in page 54.
2. While testing, connect the CASE pin and four screw bolts to shield plane, the EMI could be reduced.