Datasheet
ht tp://www.t racopower.com Page 1 of 3
DC/DC Converters
TES 2N Series, 2 Watt
Features
u Low profile SMD-package
u Wide 2:1 input voltage range
u I/O isolation 1500 VDC
u Input filter meets EN55022, class A
u Operating temperature range
–40°C to +85°C
u Short-circuit protection
u Qualified for leadfree reflow solder
process according IPC J-STD-020D.1
u Available in tape and reel package
u Bears washing process
u 3-year product warranty
Ordercode Input voltage range Output voltage Output current max. Efficiency typ.
TES 2N-0510 3.3 VDC 500 mA 70 %
TES 2N-0511 5 VDC 400 mA 73 %
TES 2N-0512
4.5 – 9.0 VDC
12VDC 165 mA 75 %
TES 2N-0513
(nominal 5 VDC)
15 VDC 135 mA 73 %
TES 2N-0521 ± 5 VDC ±200 mA 64 %
TES 2N-0522 ±12 VDC ±85 mA 69 %
TES 2N-0523 ±15 VDC ±65 mA 71 %
TES 2N-1210 3.3 VDC 500 mA 73 %
TES 2N-1211 5 VDC 400 mA 77 %
TES 2N-1212
9 – 18 VDC
12 VDC 165 mA 80 %
TES 2N-1213
(nominal 12 VDC)
15 VDC 135 mA 80 %
TES 2N-1221 ±5 VDC ±200 mA 73 %
TES 2N-1222 ±12 VDC ±85 mA 78 %
TES 2N-1223 ±15 VDC ±65 mA 78 %
TES 2N-2410 3.3 VDC 500 mA 72 %
TES 2N-2411 5 VDC 400 mA 77 %
TES 2N-2412
18 – 36 VDC
12 VDC 165 mA 80 %
TES 2N-2413
(nominal 24 VDC)
15 VDC 135 mA 81 %
TES 2N-2421 ±5 VDC ±200 mA 74 %
TES 2N-2422 ±12 VDC ±85 mA 78 %
TES 2N-2423 ±15 VDC ±65 mA 80 %
TES 2N-4810 3.3 VDC 500 mA 71 %
TES 2N-4811 5 VDC 400 mA 73 %
TES 2N-4812
36 – 75 VDC
12 VDC 165 mA 79 %
TES 2N-4813
(nominal 48 VDC)
15 VDC 135 mA 79 %
TES 2N-4821 ± 5 VDC ±200 mA 71 %
TES 2N-4822 ±12 VDC ±85 mA 77 %
TES 2N-4823 ±15 VDC ±65 mA 77 %
Models
The TES-2N series is a family of high performance 2W DC/DC converter modules
featuring wide 2:1 input voltage ranges. The 28 models come in a low profile SMD
package which requires just 3 cm
2
space on the PCB. A high efficiency allows an ope-
rating temperature range of –40°C to +85°C. A built-in EMI input filter complies with
EN 55022, class A. Typical applications for these converters are battery operated
equipment, instrumentation, communication and industrial electronics, everywhere
where isolated, tightly regulated voltages are required.
UL 60950-
1
CB
Scheme