Datasheet
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.2% max.
dual output models:
0.5% max.
- Load Variation (0 - 100%)
single output models:
1% max. (2.5 Vout models)
0.5% max. (other models)
dual output models:
1% max. (Output 1)
1% max. (Output 2)
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
Ripple and Noise
- 20 MHz Bandwidth
85 mVp-p typ.
Capacitive Load
- single output
2.5 Vout models:
2'000 µF max.
3.3 Vout models:
2'000 µF max.
5.1 Vout models:
2'000 µF max.
12 Vout models:
430 µF max.
- dual output
12 / -12 Vout models:
200 / 200 µF max.
15 / -15 Vout models:
120 / 120 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
450 ms typ. (Power On)
5 ms typ. (Remote On)
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
150% typ. of Iout max.
Overvoltage Protection
118 - 156% of Vout nom.
(depending on model)
3.9 VDC typ. (2.5 & 3.3 Vout models)
6.2 VDC typ. (5.1 Vout models)
15 VDC typ. (12 Vout models)
18 VDC typ. (15 Vout models)
Transient Response
- Response Time
250 µs typ. (75% to 100% Load Step)
Safety Standards
- IT / Multimedia Equipment
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/thd12
Pollution Degree
PD 2
Over Voltage Category
Not mains connected
Safety Specifications
EMI Emissions
- Conducted Emissions
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
- Radiated Emissions
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
External filter proposal:
www.tracopower.com/overview/thd12
EMS Immunity
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
Ext. input component:
Nippon chemi-con KY 220 µF, 100 V
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
EMC Specifications
THD 12 Series, 12 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023